User Manual
3-24
3
Communicating with the FD-MH series
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-MH) -
3-4
Command Parameter List
The following tables list the command parameters used to read/write the settings and
status of sensor amplifiers, or to issue motion commands, by creating a handshake
control program.
For details about how the master station communicates using command parameters,
see:
 "Issuing a Motion Command to a Senso
r Amplifier" (page 3-
20)
 "Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-21)
The table below des cribes parameters which are common to the DL-CL1.
For the communication methods using these common command parameters, see
"Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-21).
Attribute R: Write; W: Read
Common Command Parameter List
 Data 
category 
(HEX) 
 Data 
number 
(HEX) 
 Name Description 
 Attribute 
 Data 
type 
Default 
value 
 Parameter range 
 00 
 **  00 to 
**    FF 
 *3 
 01 0000 
 All unit key 
lock 
 Activates key lock on all sensor 
amplifi ers connected. 
 W UINT 0 
 0: Unlock
1: Full key lock
2: Key lock 
 03 
 0000 
 Error 
information 
 Possible errors, and their contents, of 
sensor amplifi ers
Same content as remote register 
(RWr[n] + 0)
If there are errors with multiple ID 
numbers, the error information for the 
smallest ID number is reported. 
 R 
 UINT 0 *4 
 0001 
 Warning 
information 
 Not used with the FD-MH series.   - - - 
 0002 
 Error ID 
number
 *3
 Errors are read by assigning sensor 
amplifi ers (ID 01 to ID 10) to bits 0 - 9.  
  If there are errors with multiple ID 
numbers, all of the associated bits 
are set to 1.The error with DL-CL1 is 
assigned to bit 15. 
 WORD 0 
 For each bit
0: No Error
1: Error 
 0003 
 Warning ID 
number 
 Not used with the FD-MH series.   - - - 
 0101 
 Output ID 
01 
 Output state of ID 01.
Each output is assigned to the 
corresponding bit.  
*1
  Same content as remote input RX. 
 WORD 0 
 For each bit
0: Output OFF
1: Output ON 
···  ··· 
 010A 
 Output ID 
01 
 Output state of ID 10.
Each output is assigned to the 
corresponding bit.  
*1  
Same content as remote input RX. 
 0201 
 Current 
Value ID01 
 Reads the instantaneous fl ow rate 
value of ID01.
Same content as the instantaneous 
fl ow rate value in remote register RWr. 
 DINT 0  ··· ··· 
 0213 
 Current 
Value ID10 
 Reads the instantaneous fl ow rate 
value of ID10.
Same content as the instantaneous 
fl ow rate value in remote register RWr. 