User Manual
3-2 Device Maps
3-15
3
Communicating with the FD-MH series
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-MH) -
Number [n] denotes the first data memory number assigned to the DL-CL1.
*1 See  "Entering an External Input into a Sensor Amplifier" (page 3-17).
*2 See  "Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-21).
See  "Issuing a Motion Command to a Sensor Amplifier" (page 3-20).
*3 See  "Reading Current Values (Instantaneous Flow Rate) from Sensor Amplifiers" (page 3-18).
*4 See  "Error information list" (page 3-7).
*5 See  "Command response list" (page 3-8).
 Operating 
mode 
 Device no. (HEX)   Name 
Communication 
method 
 Description 
 Reading 
range 
 Monitor mode 2  
 Full mode  1 
 Full mode  2 
 RWr[n] +12 to 13
(INT32) 
 Current Value 
ID 04 
 *3 
 Used for reading the instantaneous fl ow rate 
value.
Outputs the instantaneous fl ow rate value of the 
sensor amplifi er (ID 04). 
 INT32 
(LITTLE) 
 RWr[n] +14 to 15
(INT32) 
 Current Value 
ID 05 
 *3 
 Used for reading the instantaneous fl ow rate 
value.
Outputs the instantaneous fl ow rate value of the 
sensor amplifi er (ID 05). 
 INT32 
(LITTLE) 
 RWr[n] +16 to 17
(INT32) 
 Current Value 
ID 06 
 *3 
 Used for reading the instantaneous fl ow rate 
value.
Outputs the instantaneous fl ow rate value of the 
sensor amplifi er (ID 06). 
 INT32 
(LITTLE) 
 RWr[n] +18 to 19
(INT32) 
 Current Value 
ID 07 
 *3 
 Used for reading the instantaneous fl ow rate 
value.
Outputs the instantaneous fl ow rate value of the 
sensor amplifi er (ID 07). 
 INT32 
(LITTLE) 
 RWr[n] + 1A to 1B
(INT32) 
 Current Value 
ID 08 
 *3 
 Used f
or reading the instantaneous fl 
ow rate 
value.
Outputs the instantaneous fl ow rate value of the 
sensor amplifi er (ID 08). 
 INT32 
(LITTLE) 
 RWr[n] + 1C to 1D
(INT32) 
 Current Value 
ID 09 
 *3 
 Used for reading the instantaneous fl ow rate 
value.
Outputs the instantaneous fl ow rate value of the 
sensor amplifi er (ID 09). 
 INT32 
(LITTLE) 
 RWr[n] +1E to 1F
(INT32) 
 Current Value 
ID 10 
 *3 
 Used for reading the instantaneous fl ow rate 
value.
Outputs the instantaneous fl ow rate value of the 
sensor amplifi er (ID 10). 
 INT32 
(LITTLE) 
 RWr[n] +20 to 21
(INT32) 
 (Not used)   - - - 
 RWr[n] +22 to 23
(INT32) 
 (Not used)   - - - 
 RWr[n] +24 to 25
(INT32) 
 (Not used)   - - - 
 RWr[n] +26 to 27
(INT32) 
 (Not used)   - - - 
 RWr[n] +28 to 29
(INT32) 
 (Not used) 
 - - - 
 R
Wr[n] + 2A to 3F 
 System 
reserved 
 - Unusable - 