User Manual
3-2 Device Maps
3-14
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-MH) -
Communicating with the FD-MH series
3
Number [n] denotes the first relay number assigned to the DL-CL1.
*1 See  "Entering an External Input into a Sensor Amplifier" (page 3-17).
*2 See  "Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-21).
See  "Issuing a Motion Command to a Sensor Amplifier" (page 3-20).
*3 See  "Rewriting a Setting Value of a Sensor Amplifier" (page 3-21).
 Remote Register RWr (DL-CL1 -> Master Station)
 Operating 
mode 
 Device no. 
(HEX) 
 Name 
 Communication 
method 
 Description Reading range 
 Monitor mode  2 
 Full mode  1 
 Full mode  2 
 RWr[n] + 00   Error code   - 
 Stores an error code when error state (RX[n] 
+ 0F) turns ON. 
 *4 
 RWr[n] + 01 
 Command 
response 
 *2 
 Used when communicating under handshake 
control program.
Stores details of command execution result. 
 *5 
 RWr[n] + 02 
to 03
(2 words) 
 Read data   *2 
 Used when communicating under handshake 
control program.
Stores the parameter data read from the 
sensor amplifi er. 
 The data type 
depends on the 
parameter type. 
 RWr[n] + 04 
 Integration reset 
input response 
 *1 
 Stores the integration reset input response of 
the sensor amplifi er.
The response is output by assigning sensor 
amplifi ers (ID 01 to ID 10) to bits 0 - 9. 
 0: Input OFF
1: Input ON 
 RWr[n] + 05 
 Flow rate hold 
reset input 
response 
 *1 
 Stores the fl ow rate hold reset input response 
of the sensor amplifi er.
The response is output by assigning sensor 
amplifi ers (ID 01 to ID 10) to bits 0 - 9. 
 0: Input OFF
1: Input ON 
 RWr[n] + 06   (Not used)   - - - 
 RWr[n] + 07 
 Temperature 
hold reset input 
response 
 *1 
 Stores the temperature hold reset input 
response of the sensor amplifi er.
The response is output by assigning sensor 
amplifi ers (ID 01 to ID 10) to bits 0 - 9. 
 0: Input OFF
1: Input ON 
RWr[n] + 08 (Not used)   - - - 
 RWr[n] + 09 
 Current value 
"invalid" 
 *3 
 If instantaneous fl ow rates from sensor 
amplifi ers (ID 01 to ID 10) are invalid (-----), 
they are output by assigning them to bits 0 - 9. 
 0: Normal value
1: Invalid 
 RWr[n] + 0A 
 Current value 
"over" 
 *3 
 If instantaneous fl ow rates from sensor 
amplifi ers (ID 01 to ID 10) are "over"(FFFF), 
they are output by assigning them to bits 0 - 9. 
 0: Normal value
1: Over 
 RWr[n] + 0B 
 Current value 
"under" 
 *3 Not used with the FD-MH series.   - 
 RWr[n] +0C 
to 0D
(INT32) 
 Current Value 
ID01 
 *3 
 Used for reading the instantaneous fl ow rate 
value.
Outputs the instantaneous fl ow rate value of 
the sensor amplifi er (ID 01). 
 INT32 (LITTLE) 
 RWr[n] +0E 
to 0F
(INT32) 
 Current Value 
ID02 
 *3 
 Used for reading the instantaneous fl ow rate 
value.
Outputs the instantaneous fl ow rate value of 
the sensor amplifi er (ID 02). 
 INT32 (LITTLE) 
 RWr[n] +10 
to 11
(INT32) 
 Current V
alue 
ID03
 *3 
 Used for reading the instantaneous fl ow rate 
value.
Outputs the instantaneous fl ow rate value of 
the sensor amplifi er (ID 03). 
 INT32 (LITTLE) 