Owner's manual
KEYENCE CORPORATION. Vision System Division
‐ 9 ‐ www.keyence.com
2
1
3. Outputting the Measured Value/Judged Value (PLC-Link) [Keyence KV Series]
✎Configuring the Output Settings
Press "Select Data", and select the target data to output.
Open "Output Settings", and select "PLC- Link".
3
After finishing data addition, press "OK". Check the data to output and the data memory address.
Set the measured values/judged values to output in "Output Settings". This section describes how to assign tool measurement
values/judgment values.
(In the description, the following are output: 1: Total Status Value, 2: T100: Pattern Search. Pattern X Position Result, 3: T100:
Pattern Search. Pattern XY Position Result, 4: T101: Area. Area Result, 5: T102: OCR. Recognized Character (String), 6: T100:
Pattern Search. Judged Value, 7: T101: Area. Judged Value, 8: Program Time, 9: Total Count)
When added, the result output unit opens.
The added output data and the list of data
memory address to which the data is
output are displayed.
The s
tart of the data memory address is
specified in "Result Output Address" on
[Global] > [Communications & I/O] > [PLC
‐
Link
] (Address 500 in the above example).
See the next page for the output format
when storing in the data memory.
Items that can be output are
categorized into "Measured Value",
"Judged Value", and "Variables".
Select an item to output from these
categories and press "Add" to add the
item.
You can change the output order of the
added items, or delete the items.