Owner's manual
KEYENCE CORPORATION. Vision System Division
‐ 5 ‐ www.keyence.com
5
Select [Convert] > [Auto-assign relay/DM] in the Unit Editor to assign a device.
6
Save the changes and exit the Unit Editor.
7
Select [Monitor/Simulator] > [Transfer to PLC] in KV STUDIO.
8
Restart both the CV-X Series and the KV Series.
If "Initializing PLC- Link..." appears on the lower left of the screen and
disappears immediately, it indicates that the link has been established
successfully.
If the link establishment has failed, the message "Initializing PLC- Link... *"
appears repeatedly, and the error message "Failed to establish a link with
the PLC" appears.
Check the settings of the CV‐X Series and KV Series again.
Alternatively, you can use this icon.
Alternatively, you can use this icon.
* S
tart the KV Series first, and then start the CV
‐X Ser
ies.