Owner's manual

KEYENCE CORPORATION. Vision System Division
‐ 16 ‐ www.keyence.com
Command Execution Procedure Example: Switch Program Setting No. (PW)
Here is an example of a representative command execution procedure. This section explains an example of executing the PW
(Switch Program Setting No.) command, which uses a command parameter, with Command Execute Event set to "Polling". The
screens with blue frames show when the "Registration monitor" function of KV STUDIO is used for confirmation.
1
Check the PW (Switch Program Setting No.) command operation.
1. Enter "24", the PW command No., in the data memory
corresponding to the PLC Command Address (DM100 in this
example), and the parameters switch target SD drive No. and
program No. The figure on the right shows an example of
switching to program No. "23" on "SD1".
* The address to use is 1 word for Command No. and 2 words
for other parameters.
2. Enter 1 in the data memory corresponding to the PLC
Command Execution Address (bit) (DM002 in this example).
* The address to use is 1 word.
3. The command is executed.
4. Check if the values of the data memory corresponding to
the PLC Command Complete Address (bit) and Command
Result Address (DM003 and DM200 respectively in this
example) have changed.
When the command is successful: CVX writes "1" into Command
Complete Address (bit), and "0" into Command Result Address.
When the command fails: CVX writes "1" into Command
Complete Address (bit), and an error code into Command Result