Owner's manual
KEYENCE CORPORATION. Vision System Division
‐ 15 ‐ www.keyence.com
✎
Command Execution Procedure Example: Save Settings (SS Command)
Here is an example of a representative command execution procedure. This section explains an example of executing the
SS (Save Settings) command, which does not use a command parameter, with Command Execute Event set to "Polling". The
screens with blue frames show when the "Registration monitor" function of KV STUDIO is used for confirmation.
1
Check the SS (Save Settings) command operation.
1. Enter "12", the SS command No., in the data memory
corresponding to the PLC Command Address (DM100 in
this example).
* The address to use is 1 word.
2. Enter 1 in the data memory corresponding to the PLC
Command Execution Address (bit) (DM002 in this
example).
* The address to use is 1 word.
3. The command is executed.
4. Check if the values of the data memory
corresponding to the PLC Command Complete Address
(bit) and Command Result Address (DM003 and DM200
respectively in this example) have changed.
When the command is successful: CV‐X writes "1" into Command
Complete Address (bit), and "0" into Command Result Address.
When the command fails: CV‐X writes "1" into Command Complete
Address (bit), and an error code into Command Result Address.