User guide
3
After 4 sec 
of no key 
operation.
Reference value*
Press for 3 sec or more.
+
+
Increase the 
setting.
Decrease the 
setting.
Operating mode
Standard
Focus mode
AP-C30/C
35
AP-C31/
C31P/C33
/C33P
When 
operating 
mode is
• Two-point tuning
• Active tuning
Display color (7-segment)
ON: Red, OFF: Green
ON: Green, OFF: Red
Normally red
Normally green
Within set value: Green 
Outside set value: Red
Detection range (AP-C30/C35)
Positive pressure range
Compound pressure range
Negative pressure range
Focus center pressure
■ Toggling the 
  display
■ Manual configuration 
Settings are 
manually 
configured. The 
display changes 
for each mode.
* Toggling the 
display of 
settings (see the 
diagram below).
* Manual 
configuration 
only during F-3/A-
2 mode operation.
Current value
Peak hold
Bottom hold
* The reference value is 
the pressure value when 
zero shift input is 
received and is replaced 
only when zero shift 
input is selected.
■ Mode 
  configuration
Current value
Reference value
Hold value
Detection mode
General-purpose mode
Variable hysteresis mode
Window mode
Application mode 1
Application mode 2
Zero shift input
Analog output
N.O./N.C.
N.O.
N.O.
N.C.
N.C.
N.O.
N.C.
N.C.
N.O.
Control 
output 1
Control 
output 2
2.5  msec
5  msec
100  msec
500  msec
Analog/zero shift
Chatter prevention
Sets response time.
• N.O. = normal open.
• N.C. = normal close.
Standard
Eco mode
Power-save
*  See the Focus Mode section 
of Part 9 for the center 
pressures that can be 
selected.
* F-1 and F-2 mode only
Values that fall between the P1 
and P2 settings will be 
displayed in green, while values 
outside that range will be 
displayed in red.
*
When 
A-1/A-2 is 
selected
The display color 
is independent of 
the control output.
The conditions of 
ON/OFF in the 
right table is the 
case when N.O. 
is set.
during 
fixed mode 
operation
( )
8.  Sensor Configuration
■
 Toggling the display of settings
● 
General-purpose mode/F1
● 
Variable hysteresis mode/F-2
● 
Window mode/F-3
● 
Application mode 1/A-1
● 
Application mode 2/A-2
■ 
Two-point tuning (F-1/F-2)
The sensor is made to detect the pressures when the target object is 
present and then absent for confirmation of target suction pick-up, and 
the intermediate value is used.
Control output 1 configuration: When P1 (H1) is selected on the settings 
display.
Control output 2 configuration: When P2 (H2) is selected on the settings 
display.
Flashes 
for 3 sec.
Setting
Target object 
present
Target object 
absent
■ 
Active tuning (A-1)
See Section 10.
Note: • Press and hold the MODE button ( ) for at least 3 seconds to return to the current 
value/reference value/hold value display from each of the mode setting screens.
• Press the left side   on the manual adjustment button ( ) while holding down the 
mode button ( ) to return to the previous display.
• The current value will be displayed based on the ambient pressure conditions prevalent 
at that time without regard to zero shift input when the P2 setting display is selected for 
A-1 mode or when the Hi and Lo setting displays are selected for A-2 mode.
• The sensor must be configured manually when operating in the F-3/A-2 modes. The 
SET button ( ) will not function.