User guide
1
Ultra-compact Digital 
Pressure Sensor 
AP-C30 (P) Series
Instruction Manual
1.  Safety Precautions
WARNING
●
 Do not use this product in safety circuits such as those designed to 
protect human workers.
●
 This product  does  not  employ  an  explosion-proof  construction. Do 
not use it in the presence of flammable gasses, liquids, or powders.
●
 This is a direct current power supply type sensor. Application of an 
alternating current may result in explosion or fire.
■
 Accessories
3.  Pipe Connections
You can select from one of two pressure ports: one on the back of the 
sensor that can accommodate a pipe leading directly away from the back 
of the sensor, and one on the side of the sensor to accommodate a pipe 
leading away from the sensor at a right angle. 
1) The pressure port is 1/8 of Rc (PT). Commercially available air pres-
sure joints and nipples can be used with the port.
  When attaching the joint,  use a wrench to  hold  the pressure port in 
place as illustrated below.
Hold in place 
with wrench 
(12mm).
2) Attach the included valve plug to the pressure port not being used.
Hold in place with 
wrench (12 mm). 
Hexagonal 
wrench (5mm)
Valve plug with 
hexagonal hole
CAUTION
• Do  not use  a  torque  in excess of  10  Nm  when tightening  the joint. 
Doing so may damage the joint.
• Apply sealing tape when attaching the joint in order to prevent air leaks.
4.  Mounting Brackets (option)
Dedicated mounting hardware  is available for the  sensor, allowing it  to 
be installed in a range of locations.
 Horizontal mounting bracket  Wall mounting bracket 
  (AP-BO1)  (AP-BO2)
  Faceplate/ceiling mounting bracket  Tilted mounting bracket
  (AP-BO3)  (AP-BO4)
Substitution bracket 
(AP-BO5)
●
 1 connector cable (2 m)
●
 1 unit scale label
  (AP-C33 only)
2.  Part Names
SET AP-C33 MODE
MPa
21
Pressure display unit
Pressure display
Mode button
Manual adjustment button
Set button
Wiring 
connector
Pressure 
port (rear)
Pressure port
 (side)
Mounting screws 
(M3 x 2)
Operational indicator 
  Output 1  Output 2
1 2
Approx. 90
●
 1 valve plug with hexagonal hole 
●
 1 instruction 
manual
96M1312
1.  Safety Precautions
2.  Part Names
3.  Pipe Connections
4.  Mounting Brackets (option)
5.  Connection Method and Diagrams
6.  Precautions for Safe Use
7.  Detection Mode Operation
8.  Sensor Configuration
9.  Explanation of Features
10
.  Active Tuning
11
.  Default Mode Settings (Initialization)
12
.  Specifications
13
.  Ambient Pressure Compensation
14
.  Key Lock
15
.  Error Displays and Corrective Actions