User's Manual

2-13
2
First Steps
2-5
Establishing a Connection
The BL-N90/N90K and the communication unit communicate as a pair. This section describes
how to establish a connection between the BL-N90/N90K and the communication unit.
Procedure
1 Press the "Trigger" switch to activate the laser.
2 Scan the barcode attached to the communication unit.
After 10 to 30 seconds, a connection will be established. Once a connection is established, the
devices will be in the following state:
The blue LED on the scanner is lit.
The blue LED on the communication unit is lit.
Note
Perform the following operation with the communication unit connected to your
computer ( page 2-5).
Note
The following symptoms indicate that a connection is not established.
The blue LED on the scanner is flashing
The blue LED on the communication unit is flashing
At this stage, perform the following steps.
Note that even when using multiple BL-N90/N90K scanners, each scanner can only
communicate with its pair communication unit ( page 2-14).
100mm