Installation Manual

Frost Protection
The C90 and C110 have an integral frost protection thermostat. However, care
should also be taken to ensure that any exposed pipework is adequately insulated to
prevent freezing.
Error Codes
In the event of a fault causing a module shutdown the display will show an error
message “E nn”.
Low water pressureE 44
Return thermistor open circuit - check/replace connections/thermistorE 37
Flow thermistor open circuit - check/replace connections/thermistorE 36
Return thermistor short circuit - check/replace connections/thermistorE 32
Flow thermistor short circuit - check/replace connections/thermistorE 31
Difference between flow and return temperatures too high. Check circulation.E 30
Flow temperature increased too quickly. Check water circulation.E 25
Maximum return temperature exceeded. Check circulation.E 19
Flow overheat - check water circulationE 18
Thermal fuse blown or flue overheat thermostat activated.E 12
Internal electronics error - rest or replace control boxE 11
Power has been reset whilst module was in lockoutE 04
Gas valve faulty or not connectedE 03
No ignition after restart. Check gas supply, gas valve operation, ignitor electrode spark
generation.
E 02
Flame detected when not expected. Check module earth and probe condition.E 00
Description of faultDisplay
Gas Leak or Fault
If you suspect a gas leak turn off the appliance immediately, turn off the gas
tap to the appliance and contact your local gas region without delay.
If you suspect a fault with the appliance it must not be used until the fault has
been corrected by a competent person.
In the unlikely event of a breakdown consult your Installer or Service Engineer and
advise the fault display and description of fault.
The boiler should be installed and serviced only by CORGI registered operatives. All CORGI
registered Installers carry a CORGI ID card, and have a registration number. You can check your
installer by calling CORGI direct on 01256 372300.