BEFORE FIRST USE: To prevent any internal damage, it is very important to keep refrigeration units (like this one) upright throughout their journey. Please |save it standing upright and outside the box for 24 HOURS before plugging tin.
Thank you for purchasing our dehumidifier. Keynotes wishes our products and services can bring convenience to your work and life. We highly recommend you to keep the manual for reference, in case you encounter unexpected issues using this unit. Please read the manual carefully to ensure proper use of the dehumidifier. Our dehumidifiers are widely used in family bedrooms, bathrooms, basements, offices and storage rooms, etc.
The graphics and functions provided in this manual may not be the same as the actual product. Please always refer to the actual product. The model of the machine on the manual is for reference only. Please operate the machine based on the actual product. The right to interpret the relevant terms belongs to the company.
Install the dehumidifier on flat surface to minimize vibration and/or noise. Inspect the power cord before use. Never operate the dehumidifier when the power cord or plug is damaged. Insert the three-prong plug on the power cord into a matching electrically grounded outlet (120V/60Hz, 15A at least). Do not use an adapter. Never cut off the third prong. Do not use an extension cord. Do not operate the dehumidifier in standing water. Keep motor and wiring dry.
3. Whesls 2.Handle 1.Handle Bar Blair Filter air Inlet 4.Control Panel oy 3.Cord Winder 2.Pump Drain Outlet 1.Air Outlet 6.Emergency Drain Outlet 5.Pump Reservoir 4.
Setting Humidity The humidity level can be set within a range of 10%RH to 98%RH in 1% increments. When it starts work, it will first automatically detect and show the room's humidity. Press the "UP" button to change the humidity selection in 1% increments.Press "DOWN" to make it decrease by 1%RH. "52" Flash and show the setting humidity. When the humidity level is set at 30%RH, the dehumidifier will work at continuous dehumidifying mode.
Auto Defrost When the frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run until the frost disappears. Auto-Restart If the dehumidifier shuts off unexpectedly due to power being cut, the dehumidifier will restart with the previous function setting automatically when the power resumes. Auto Drain Thanks to the built-in pump, the dehumidifier will drain the condensation water automatically.
When the machine is defrosting, the defrost indicator :foremost will be flashing, defrosting end the light goes out. When the pump is draining, PUMP Indicator «rue will be flashing. When set or check the timer, the timer indicator me: will be flashing. When the timer is setup properly the indicator nes = will light up, light goes out when timer function is not activated. When the fan delays to start, running indicator sun: will be flashing; it will light up when the fan is running. 1.
Number Eur Code 1 EP Name of The Fault Water pump failure Note 1.Tum off the dehumidifier and unplug it; 2. Find the gravity drain outlet at the bottom of the dehumidifier and connect the emergency hose to drain; 3.After emptying the reservoir, close the gravity drain outlet; 4.Connect the pump drain hose; Re-plug and start the dehumidifier to check the pump function. 2 EC Control Panel Failure The dehumidifier will not be ready for operation.
Attention When the machine signals the alarm, it will flash or display the alarm, in case there are multiple errors on the unit, it will display the errors in tum. When one of above malfunctions occurs, the buzzer will alarm for a few seconds, press any key during the alarm to release the alarm sound. If the malfunction is still present, please don't hesitate to contact Keynotes Customer Service email: for help.
1. Take out 4 screws and a handle from the accessories, and put the handle into the groove at the back of the humidifier, making the screws correspond to the screw holes. 2. Tighten all the four screws on the hands respectively, the installation is finished. Put the handle into the groove Tighten all the four hand screws, at the back of the dehumidify complete the installation. making the 4 screws correspond to the screw hole.
This dehumidifier has an internal pump that will automatically drain the condensate out via the long drain hose. Before muting on the dehumidifier, make sure the hose has been connected to the drain outlet properly. 1. Uncoil the entire hose; 2. Attach the hose to the drain outlet; 3. Place the unattached end of the hose in a sink, drain bucket or outdoors: Anywhere that the water can drain out safely (Please ensure that no kinks or other obstructions will stop the water to flow).
In power-disconnected status, tilt the dehumidifier as the figure shown, pull out the rubber plug and put the dehumidifier straight to drain the sewage in the water tank.
Tum the dehumidifier off and remove the plug from the wall outlet before cleaning A-Cleaning the Dehumidifier Clean the dehumidifier housing with a soft damp cloth. Do not submerge or place water on the dehumidifier or control panel. Water may damage the electronic components of the dehumidifier. Do not use chemical solvents such as benzene, alcohol, gasoline or other heavy-duty cleaners. The surface may become damaged or deformed.
Check the information below for troubleshooting steps that will save you time to resolve issues that may happen with the unit. The list includes most issues but not the results of defective unit, crafts or materials in the unit. If all the troubleshooting steps have been exhausted and issue is stilling occurring, feel free to get in touch with Keynotes Customer Service to get further assistance.
The dehumidifier is titled. Place the dehumidifier on flat surface.
When using, make sure doors and windows are closed to get the best humidity removal effect. When cleaning the dehumidifier fuselage, pleads use wet lath or tells to wipe the unit's surface gently, do not splash water on the unit directly. When on continuous drainage, make sure the drainage pipe Is placed horizontally on the ground. Av old the pips to bs on unseen surface or In an arch position.
MODEL NO. PDGT701BC POWER SOURCE 120V~60Hz RATED 1150W RATED H) 103A MOISTURE 50 Pints/Day MOISTURE 90 Pints/Day MOISTURE 150 Pints/Day MOISTURE 180 Pints/Day INPUT &10w INPUT 5.5A 1.60 liters/kWh MOTOR FLA 0.92A MOTOR COMPRESSOR REFRIGERANT (570g) MAXIMUM ALLOWABLE PRESSURE 6.2MPa HIGH PRESSURE 4.0MPa LOW PRESSURE 1.
Keynotes offers a 12-month warranty to all of our products together with the original proof of purchase when a defect occurred, including these newly purchased and unused, from Keynotes or through an authorized reseller, wholly or substantially, or as a result of faulty manufacturing parts, or workmanship during the Warranty Period.