Thank you for purchasing our dehumidifier. wishes that our products and services can bring convenience to your work and life. We highly recommend that you keep the manual for reference if you encounter unexpected events using the unit. Please read the manual carefully to ensure proper use of the dehumidifier. Our dehumidifiers are widely used in family bedrooms, bathrooms, basements, offices and storage rooms, etc.
BEFORE FIRST USE: To prevent any internal damages, it is very important to keep the unit (like this one) upright throughout its journey. Please leave it standing as the picture shown below and outside the box for 24 HOURS before plugging it in.
SANELY Parts Description Control Interface. Operation Cleaning & Maintenance.. Troubleshooting. SPECIAL NOTES Technical Warranty CONSOLABLE Statement The graphics and functions provided in this manual may not be the same as the actual product. Please always refer to the actual product. The model of the machine on the manual is for reference only, please check the corresponding content and operate the machine based on the actual product. The right to interpret the relevant terms belongs to the company.
Warning Make sure to turn off and unplug the dehumidifier before cleaning. Do net touch the plug with wet hands. Do not operate or tum off the dehumidifier by plugging in or unplugging the device. Use ths control panel instead. Bs sure to run the slopping water hose downward to let the water flow out smoothly. Do not use if the power cord is broken or damaged. Do not place or operate In a wet room such as bathroom or laundry room, which may be splashed by water.
This appliance can not be used by children aged under 8 years old and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instructions concerning use of the appliance In a safe way and understand the hazards Involved. Children shall nat play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Mode Setting There're 3 available modes: Dry Clothes Mode; Dehumidify Mode and Continuous Mode. When powered on, press the "Mode" button, the device will display from the drying mode to dehumidifying mode and continuous dehumidifying mode. Each time you press the mode button, the working mode will switch accordingly. Dry Clothes Mode: Humidity and fan speed cannot be set. Dehumidify Mode: Humidity and fan speed can be set. Continuous Dehumidifying Mode: Humidity cannot be set, fan speed can be set.
2. Press and hold the " ©) " button for several seconds to make the selection of the timer faster. 3.If the time is set to 00, this is called the invalid time. If you set the timer successfully, the light" will be on. The LED screen will show the remaining time if you press the "TIMER" button, and display the current humidity automatically after a few seconds. LOCK (25) When the unit is muted on, press "LOCK" and hold on for 2 seconds, the control panel will be locked together with the other buttons.
Auto Defrost Feature When the dehumidifier is running at a lower temperature, the system will automatically determine whether there is a presence of frost. If any frost exists, it will defrost automatically. Defrost Action The fan runs at high wind speed when the compressor stops. When the device is currently powered on, only the "POWER" button light will be on indicating the device is in "Standby" Status before any operation.
The dehumidifier can be used for drying clothes in rainy weather. Step 1. Hang the washed clothes in a small space such as cloakroom, bathroom, or storage room. Note: Keep away the unit from the water drips of the washed clothes. Step 2. Open the dehumidifier and set the humidity level at 30%RH. It's the best if you let the air outlet of the dehumidifier to blow air to the clothes directly. 1.The drying effect will vary from the thickness of clothes, the number of clothes and the size of the drying space.
Humidity always shows "25% RH" —but there aa big difference from the actual humidity. Humidity sensor failure? Set the humidity to 30%RH, the dehumidifier ‘can ail continue to work, and can be weed normally. Repair and replace the humidity sensor. Humidity always shows "99% RH" — but there Is a big difference farm the actual humidity. Water on the surface of humidity sensor? ‘The dehumidifier is not affected and can ‘continua to work, and can be used normally.
Two ways are available to remove the collected water. Use the Water Tank When the water tank is already full, the Full Tank Alert indicator will light up, the dehumidifier will automatically shut down until the tank has been emptied and placed back to the unit. Ways to Empty the Water Tank Put the water tank back Pull the water tank out from the Invert the water tank to In place, the Full Tank bottom with both of your hands.
Do not remove the float from the water tank. If the float in the water tank is removed, the sensor may not be able to determine the water level stored in the tank properly that may lead to water overflow leak from the water tank. If the water tank is dirty, just use cold water or warm water to clean it. Do not use detergent, steel wool, chemically treated dust cloth, gasoline, benzene, thinner or other solvents. Otherwise, it may damage the water tank and cause it to leak.
Remove the power supply, take out the water tank, open the drainage cap, and remove the rubber plug, then insert the water hose into the continuous drainage port and put back the water tank. Connect the power supply to start the operation. The outlet of the water hose should be lower than the continuous drainage port by more than 3.9 inches, and can not be bent. (Note: The diameter of continuous drainage port is 0.63 inches.
Turn the dehumidifier off and remove the plug from the wall outlet before cleaning. A-Cleaning the dehumidifier body Please use a soft and a slightly wet textile or cloth to clean it. B-Cleaning filter Pull out the filter. Clean the filter: Use a vacuum cleaner to gently remove the dust from the surface of the filter. If the filter very dirty, clean it with warm water and mild detergent and dry it completely. Slowly insert the filter back into the machine body.
Check the information below for troubleshooting steps, it will save you time to resolve issues that may happen with the unit. The list includes most of the common cases, but not the results of defective unit, crafts or materials in the unit. If all troubleshooting steps have been exhausted and the issue is still occurring, please feel free to reach out to Keynotes Customer Service to get further assistance. bier use nation Dehumidifier does not work The power cord is unplugged.
This is to prevent the frequent machine stop working just now? Please wait for more than 3 minutes. Room humidity Is low. The dehumidifier Is designed to work In the humidity range of Above or blow this range, It will not work. Dehumidifier doss not dry the air as it should The air filter is dirty. Clean the alr fleeter. Is the alr Inlet or alr outlet obstructed? Remove the obstruction from the air inlet or outlet. The dehumidify small for ap Increase the quantity of dehumidifier.
The dehumidifier makes loud| nose wham operating The dehumidifier Is not positional levelly. Move the machine horizontal position. Is there blocking around the alr Inlet? The air filter is clogged Clean up the distortion the air outlet and intake. Is the filter installed correctly? Please check whether the packing bag of ths filter had been removed and the filter has been installed correctly. Humidifier operates continuously Check If the dehumidifier Is In Continuous Mode. Room humidity Is too high.
When using, please do not put the machine at the soft and uneven ground, avoid vibration and movement. sy When using, make sure doors and windows are closed to get the best humidity removal effect. ‘When cleaning the dehumidifier, please use the wet textile to wipe gently, do not shoot the water directly. Do not Insert thin rods and hard objects Into the machine body to avoid malfunction and danger. Please do not put objects around the bad.
MODEL DIPLOID POWER SOURCE 120V ~ 60Hz RATED 230W RATED 20A MOISTURE 9.00 Pints/Day MOISTURE REMOVAL(80 14 Pints/Day MOISTURE REMOVAL (86 25 Pints/Day MOISTURE REMOVAL(95 34 Pints/Day INPUT 128W INPUT 12A IEF( 65°F, 60%RH) 1.30 liters/kWh MOTOR FLA 023A MOTOR COMPRESSOR RLA18A LRA100A REFRIGERANT MAXIMUM ALLOWABLE PRESSURE pampas MAXIMUM OPERATING PRESSURE HIGH pampas MAXIMUM OPERATING PRESSURE LOW pampas WATER TANK CAPACITY 221 DIMENSIONS 255+255+456mm WEIGHT 13.
Keynotes offers a 12-month warranty to all of our products together with the original proof of purchase when a defect occurred, including those newly purchased and unused, from Keynotes or through an authorized reseller, wholly or substantially, or as a result of faulty manufacturing parts, or workmanship during the Warranty Period.