User manual
PLJ-GM-BA-e-1312
34
8.7.3 Tare function
This function enables individual selection of tare functions:
Tara AtAr Automatic taring turned on,
remains stored even after disconnection
Tara no Automatic taring turned off,
User can turn on automatic tare function via F6 AtAr and this will
remain active until disconnection is carried out.
(For description see chpt. 8.11)
Tara tArF Taring, including storage of last tare value.
Value is displayed showing minus sign when balance is started and
as a NET symbol on the display.
User can turn on automatic tare function via F6 AtAr and this will
remain active until disconnection is carried out.
Operation:
Display:
Selecting the menu item
P1 rEAd
Press
TARE
1.1.Fil
Repeatedly press until the following display
appears
1.3.tArA
To change your selection, press
TARE
.
AtAr
To change your selection, press .
no
To change your selection, press .
tArF
Setting will be imported by pressing
PRINT
.
1.3.tArA