User manual
PLJ-GM-BA-e-1312 
34 
8.7.3  Tare function 
This function enables individual selection of tare functions: 
Tara  AtAr  Automatic taring turned on, 
    remains stored even after disconnection 
    Tara  no  Automatic taring turned off, 
User can turn on automatic tare function via F6 AtAr and this will 
remain active until disconnection is carried out. 
    (For description see chpt. 8.11) 
Tara  tArF  Taring, including storage of last tare value. 
Value is displayed showing minus sign when balance is started and 
as a NET symbol on the display. 
User can turn on automatic tare function via F6 AtAr and this will 
remain active until disconnection is carried out. 
Operation: 
Display: 
  Selecting the menu item 
P1 rEAd 
  Press 
TARE
1.1.Fil 
  Repeatedly press   until the following display 
appears  
1.3.tArA 
  To change your selection, press 
TARE
.
AtAr 
  To change your selection, press  .
no 
  To change your selection, press  . 
tArF 
  Setting will be imported by pressing 
PRINT
. 
1.3.tArA 