User manual
2  Basic Information (General) 
It is absolutely necessary that you read and understand the operating instructions prior to 
installation and commissioning and follow the instructions during the process! 
2.1  Proper use 
The balance you purchased is intended to determine the weighing value of material to be 
weighed.  It is intended to be used as a “non-automatic“ balance, i.e. the material to be 
weighed is manually and carefully placed in the centre of the weighing plate. As soon as a 
stable weighing value is reached the weighing value can be read. 
2.2  Improper Use 
Do not use balance for dynamic weighing. In the event that small quantities are removed or 
added to the material to be weighed, incorrect weighing results can be displayed due to the 
“stability compensation“ in the balance (Example: Slowly draining fluids from a container on 
the balance.). 
Do not leave permanent load on the weighing plate.  This may damage the measuring 
system. 
Impacts and overloading exceeding the stated maximum load (max) of the balance, minus 
a possibly existing tare load, must be strictly avoided. Balance may be damage by this. 
Never operate balance in explosive environment.  The serial version is not explosion 
protected. 
The structure of the balance may not be modified.  This may lead to incorrect weighing 
results, safety-related faults and destruction of the balance. 
The balance may only be used according to the described conditions. Other areas of use 
must be released by KERN in writing. 
2.3  Warranty 
Warranty claims shall be voided in case   
- Our conditions in the operation manual are ignored 
- The appliance is used outside the described uses 
- The appliance is modified or opened 
- mechanical damage and damage caused by media, liquids 
- natural wear and tear 
- The appliance is improperly set up or incorrectly electrically connected 
- The measuring system is overloaded 
2.4  Monitoring of Test Resources 
In the framework of quality assurance the measuring-related properties of the balance and, 
if applicable, the testing weight, must be checked regularly.  The responsible user must 
define a suitable interval as well as type and scope of this test. Information is available on 
KERN’s home page (www.kern-sohn.com) with regard to the monitoring of balance test 
substances and the test weights required for this. Our accredited DKD calibration laboratory 
offers fast and inexpensive adjustment for test weights and weighing balances (reset to 
national normal weight). 