6.2.2.1  Add mode 
This function is used to increase the counting accuracy by increasing the reference 
quantity. It can thereby be avoided that an inadequate reference unit is used, as this 
could lead to inaccurate results.  
When applying this function, the necessary minimum number of items is automati-
cally ensured. 
Operation 
Display 
1.  Carry out item 1-5 as in 
chap. 6.2.2 “Parts counter“. 
e.g. place 10 items on the weighing 
plate. 
2.  Operate the   key. 
The reference weight of the 10 items is 
stored. 
Counting accuracy can be increased by 
carrying out the following steps.  
3.  Doubling the items to be weighed: 
Apply a further 10 items (approx.). 
Operate the   key 
The reference weight of the 20 items is 
stored. 
         Pcs 
 M  on   10 
         Pcs 
 M     10 
         Pcs 
 M     20 