Instruction Manual
HK-D
HK-D-BA-e-1311 9
Press the or key to move the cursor to YES .
Then press the ENTER key to confirm the deletion of
the latest single measured value.
Press the
or key to move the cursor to NO .
Then press the ENTER key to cancel the deletion.
Deletion can be also cancelled by pressing the ESC key
wherever the cursor is located.
Single measured value can be viewed by press
or
key, and the average value or latest measured
value can be showed again by press ESC key. The
viewing sequence is different by press
or
key.
Measurement can be finished by press Average key in
case of impact times setting has not been achieved, and
the average value will be displayed.
LCD back light can be turn on or off by press key.
Press MENU or ENTER key to return to main
interface.
Press MENU key to enter main menu interface.
Shortcut key setting:
Impact direction setting can be changed by press
DIREC. key.
Impact times setting can be changed by press TIMES
key, the current impact times can be showed by press
TIMES at the first time; the counting will add 1 when
press TIMES once, and it will return to 1 if times of 32
is achieved.
Hardness scale setting can be changed by press
HARD key. Whenever press the key once, a circulating
conversion among all hardness scales that available to
current material and impact device will be performed. The
hardness scale will be changed into Leeb hardness if the
current setting is strength measurement.
Material setting can be changed by press MAT’L key.
Whenever press the key once, the circulating conversion
among all material setting will be performed, and hardness
scale will be changed into Leeb hardness, therefore,
material should be set firstly when measuring, then
hardness scale should be set.
Note: what is called “conversion” refers to the
corresponding relationship of Leeb Hardness and
other hardness for a certain material, which
established on basis of abundant tests. According to
the conversion relationship, the Leeb hardness value
which measured will be changed into other hardness
scale value automatically via calculating by hardness
tester.
6.4 Menu structure diagram
The parameter setting and additional function of equipment
can both realized by menu operating. At the main display
interface, pressing MENU key to enter the main menu.
6.5 Measuring condition setting
When you are in main display interface, press MENU
key to enter the main menu.
Press ENTER key to enter TEST Set menu. Press
】【 key to move cursor to the item which will be
set, then press ENTER key.
Note: 1. If the
Hard/σ
b
is set to
Hard
, hardness
scale could not be selected obviously. Therefore, the
cursor will skip over the item
Hardness
while
moving.
2. Only D/DC type impact device is provided with the
function of strength measuring, therefore, cursor can
not be moved to item
Hard/σ
b
when other type of
impact device is used.
3. The symbol on the left bottom of menu shows the
menu is not end, which can be paged down by press
key; The symbol on the top of menu shows
the menu is not end, which can be paged up by press
.