Owner's manual

6.2 Overview
Function
Available
settings
Description
F0 bk
Display background
illumination
bk on Background illumination on
bk off Background illumination off
bk AU Background illumination switches on
automatically when loaded or a button is
pressed
F1 AZ
Autozero
AZ 0.5d
Automatic zero correction (auto-zero) on change of
display,
Selectable digits available
0.5d,1d, 2 d, 4 d.
AZ 1d
AZ 2d
AZ 4d
F2 Unt
Standard weighing
unit
Ut lb
Pound
Ut kg
Kilogram
Ut N
Newton
F3 CHk
Check weighing
Ck Lo
Lower limit value, input see chap. 5.9
Ck Hi
Upper limit value, input see chap. 5.9
F4 CAP
Capacity
1000 kg
Weighing range [Max],
options
1000 / 2000 / 3000 / 5000 /
10000 kg
Modifications may
only be carried out
by a specialist with
competent
knowledge.
2000 kg
3000 kg
5000 kg
10 000 kg
F5 CAL
Adjustment /
linearization
nonLi Adjustment
Line Linearization
F6 isp XXXXX Internal A/D converter value
F7 GrA Not documented
F8 rst Reset to default setting
F9SPd
Display speed
SPd 7.5
SPd 15
SPd 30
SPd 60
F10of
Autom. switch-off
function
(auto off)
Off 0
Off 0: Autom. switch-off function disabled
Off 3
Off 3/5/15/30: Balance will switch off after x
minutes in stand-by mode.
Off 5
Off 15
Off 30
* = default setting
HFA-BA-e-1511 31