4.0 Cable Requirements
4.1 RS-232 Serial Cable
four conductor, shielded, stranded, AWG 24 wire (such as Belden 9534 or a larger
gauge)
50 feet maximum length (per RS-232 industry specification)
4.2 RS-485 Network Cable
two conductor, shielded, twisted pair, stranded, AWG 24 wire (such as Belden
9501 or a larger gauge)
16,000 feet total network length
refer to the Network Wiring Application Note (P/N 01824-002) for specific
network wiring information
4.3 Input Power
two conductor, stranded, AWG 18 wire (such as Belden 8461 or a larger gauge)
200 feet maximum cable length for systems using an SB-293 with two readers
NOTE: On long power cable runs, the resistance in the cable itself causes a drop in
voltage at the end of the run. Be sure that your power supply does provide 12 VDC at
the end of the cable run.
4.4 Earth Ground
single conductor, AWG 18 wire (or a larger gauge)
1
1. Ground wire is green with or without yellow tracer.