4.2 Do Not
Make modem phone line connections through PBX telephone switching systems - most
modems are not compatible with PBX systems leading to disconnection problems with the
modem.
Locate the LC-500W controller near EMI sources - EMI sources can affect the performance of
the controller.
Use switching power supplies - they are EMI sources.
Route network and reader cables beside power cables - transients on the power cables may be
picked-up by network and reader cables.
Stretch or over-tension cables.
Route cables over sharp objects.
Let the cables get tangled.
Mix LC-500Ws with PXL-100s in the same network.
Connect earth ground to the network cable shield - the LC-500W automatically connects earth
ground to the shield at one point on the network to prevent ground loops.
Use gender changer plugs when making RS-232 serial communication connections (unless you
know it is a "straight-through" plug) - gender changers may have internal wiring changes that
can disrupt communications.