5.2.3 Reader/Amplifier Daisy-Chain
One Wiegand reader is shared by all elevator control panels in an elevator control application. The
Wiegand reader connections are made to the master LC-502W elevator panel, through a Wiegand
Distribution Amplifier (P/N 04197-001 – see Figure 8).
Figure 8: Wiegand Distribution Amplifier
Make the Wiegand reader to Distribution Amplifier connections per the information in Table 3
and Figure 9 on page 15.
Make the Distribution Amplifier to master elevator panel connections per the information in
Table 4 and Figure 9 on page 15.
Table 3: Wiegand Reader to Distribution
Amplifier
Reader Amplifier WDA-TB-1
Data0 Pin 1
Beeper Pin 2
Power Pin 3
Ground and Cable Shield Pin 4
Green LED (Dual) Pin 5
Red LED (Single) Pin 6
Data1 Pin 7