User Manual
42
7. Operation
7.1 Control unit
Selector switch Reaction of the C10 circulation pump
Position -0-
Circulation pump and screw-in heater are out of operation.
The indicator lamp does not light up.
Position -1-
Circulation mode
• The circulation pump is running => The water is circulating in the
ring pipe.
• The screw-in heating element is switched off.
Position -2-
Circulation and heating mode
• The circulation pump is running. => The water is circulating in the
ring pipe.
• The screw-in heating element is ready for operation.
• The screw-in heating element is switched on when the flow tempe-
rature falls below the set value. The red LED lamp on the control unit
lights up.
• After the flow temperature is reached, the heating element switches
off. The red LED lamp goes out.
• After the flow temperature falls below the set value, the heating
element switches on again.
7.2 Circulation pump
Supply voltage 1 ~ 230 V +10 %/-15 %, 50/60 Hz
Protection type IP X4D
Ambient temperature +25 °C 0 °C to +70 °C
Max. operating pressure 10 bar (1000 kPa)
• Message display
• LED lights up green in normal operation
• LED lights up/flashes in the event of a fault (see Section 10.1)
• Display of the selected control mode Δp-v, Δp-c and constant speed
• Display of the selected characteristic (I, II, III) within the control
mode
Important!
Factory setting: Constant speed, characteristic curve III. In continuous operation, the pump should always be operated at constant
speed - characteristic curve III. The full operating instructions for the circulation pump can be downloaded from the Kerbl website.
7.3 Heating element
Connection voltage 230 V / L1 / N / PE / 50 Hz
Protection type IP 54
Temperature controller (TR) 5 - 35 °C
Stop left: 5 °C
Stop right: 35 °C
Factory setting (TR) 5 °C on, 15°C off
Safety temperature limiter (STB) 95 °C - 8 K
General tolerances are not valid for basic dimensions of semi-finished parts!
The general tolerances are only valid and applicable on shown nominal sizes
and geometric sizes!
Break and debure sharp edges!
von
Copyright:
"Weitergabe sowie Vervielfältigung dieser
Dokumente, Verwertung und Mitteilung seines
Inhalts sind verboten, soweit nicht ausdrücklich
gestattet. Zuwiderhandlungen verpflichten zu
Schadenersatz. Alle Rechte für den Fall der
Patent-, Gebrauchsmuster- oder
Geschmacksmustereintragung vorbehalten."
Albert KERBL GmbH
Felizenzell 9
D- 84428 Buchbach
"The copying, distribution and utilization of this
documents as well as the communication of its
contents to others without expressed
authorization is prohibited. Offenders will be
held liable for the payment of damages. All
rights reserved in the event of the grant of
patent, utility model or ornamental design
registration."
Albert KERBL GmbH
Felizenzell 9
D - 84428 Buchbach
"Toute communication ou reproduction de ce
document, toute exploitation ou communication
de son contenu sont interdites, sauf
autorisation expresse. Tout manquement à
cette règle est illicite et expose son auteur au
versement de dommages et intéréts. Tous
droits réservés pour le cas de la déliverance
d'un brevet, d'un modèle d'utilité ou d'un
modèle de présentation."
Albert KERBL GmbH
Felizenzell 9
D - 84428 Buchbach
1
2
A3
STAT.
REVISION NOTE
DATE
NAME
Urspr.
Baugruppe / Assembly
Assembly - Electrical components
jrieder
15.9.2021
NORM
CHECK
DRAW
NAME
DATE
DET. SCALE
1:2,5
SCALE
BASE SIZE/SEMI-FINISHED PART
MATERIAL:
von
Blatt
26867
DWG NO.
TITLE:
ARTICLE
NUMBER
KERBL:
223130-05
ISO 5456-2 Projection
methode1
Albert KERBL GmbH
l
Felizenzell 9
l
D-84428 Buchbach
Fon +49 (0)8086 - 933-100
l
Fax +49 (0)8086 - 933-500
Mail info@kerbl.com
l
www.kerbl.com
General tolerances
ISO 2768 - mK
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS
PROJECT
NUMBER
KERBL:
700354
1171,592 g
FINISHED SURFACE:
WEIGHT IN GRAMM
(WITHOUT FINISHED SURFACE):