User Manual
35
2.3 Safety devices
The unit is equipped with the following safety devices to prevent hazards to persons and objects:
Switch In switch position 0, the circulation pump and the heating element are switched off.
Temperature limiter in the heating
element
The temperature limiter STB serves as a switch-off safety device in the event of a failure of the
temperature controller.
Red LED display on the control unit
The LED lamp lights up when the temperature controller switches on the heating element and
the water is heated.
Safety valve 5 bar (included)
The safety valve is used to control the pressure on heat generators in closed systems. When the
set pressure is reached, the valve opens and prevents dangerous limit values from being excee-
ded by releasing the pressure.
Automatic bleeder valve 3/8" (flow
pipe)
The quick exhaust valve is used to completely vent the flow pipe. Remaining air pockets can
permanently damage the heating element.
Automatic bleeder valve 3/8" (included)
The enclosed bleeder valve must be installed at the highest point of the entire piping system in
a permanently frost-proof area in a vertical position.
3. Description
3.1 Intended use
Caution!
The circulation pump is used exclusively for tempering and circulating supply water for drinking bowls in stables. The circulation
pump circulates the water within a ring pipe. The integrated heating element prevents the water from cooling down and freezing
in a ring pipe. Chemical additives and acidification of the supply water can irreparably damage the unit.
3.2 Technical data
Model Circulation pump
Type: C10
Output: 3050 W
Electrical connection: 230 V / L1 / N / PE / 50 Hz
Protection class: IP X4D
Water connection output: 1 inch
Water connection inlet: 1 inch
Water pressure: max. 5 bar
Dimensions: L 520 x W 410 x H 285 mm
Weight: 6.7 kg
Heating element
Output: 3000 W
Protection type: IP 54
Temperature controller (TR): 5 - 35 °C
Factory setting (TR): 5 °C on, 15 °C off
Safety temperature limiter (STB): 95 °C - 8 K
Circulating pump
Output: 50 W
Protection type: IP X4D
Ambient temperature +25 °C: 0 °C to +70 °C
Max. operating pressure: 10 bar (1000 kPa)
3.3 Conversions or modifications
In the event of unauthorised conversions and modifications to the unit, any liability and warranty on the part of the manufacturer will be rendered void.
Conversions and modifications may only be carried out with the written consent of the manufacturer.