Operator Manual Firmware Ver.3.05 and higher Instruction Manual

Table Of Contents
3-24 BOP-1K-GL 022814
3.5.7.3 WAVEFORM SPECIFICATIONS
Refer to Table 1-2 for specifications applicable to waveforms created using LIST commands.
FIGURE 3-7. SAMPLE WAVEFORM
3.5.7.4 EXECUTING A WAVEFORM
These segments are programmed using the LIST:CURR:APPLy (PAR. B.57) or
LIST:VOLT:APPLy (PAR. B.79) commands. The details of the waveform segments are defined
in Table 3-6. Once the waveform segments are added to the list, the list is executed by sending
either CURR:MODE LIST (PAR. B.27) or VOLT:MODE LIST (PAR. B.94).
TABLE 3-5. SQUARE WAVEFORM FREQUENCY VS. POINTS
Frequency
(See Note)
Total Points
Frequency
(See Note)
Total Points
From To From To
0.02Hz 1.8Hz 3840 43.51Hz 58.0Hz 120
1.81Hz 2.7Hz 2880 58.01Hz 72.5Hz 90
2.71Hz 4.0Hz 1920 72.51Hz 87.0Hz 72
4.01 5.4Hz 1280 87.01Hz 108.7Hz 60
5.41 7.2Hz 960 108.71Hz 145.0Hz 48
7.21Hz 10.8Hz 720 145.2.9Hz 174.0Hz 36
10.81 16.3Hz 480 174.1Hz 217.5Hz 30
16.31Hz 21.7Hz 320 217.6Hz 261.0Hz 24
21.71Hz 27.1Hz 240 261.1Hz 435.0Hz 20
27.11Hz 32.6Hz 192 435Hz 652.5Hz 12
55.5Hz 66.5Hz 160 653 1000 10
NOTE: Time interval per point is inversely proportion to frequency variation within the range.