Operator Manual Firmware Ver.3.05 and higher Instruction Manual

Table Of Contents
BOP-1K-GL 022814 1-9
SAVE/RECALL CHARACTERISTICS
(See PAR. 3.5.7)
Number of Locations 99
15 locations available to be implemented on
power-up
Parameters Saved or Recalled All parameters saved for power-up
Mode of operation Voltage, Current or External For External the operating mode is deter-
mined by signal at I/O Port; no signal selects
voltage mode (see PAR. 3.4.1).
Reference type Internal, External or
External Reference Level
Main channel
Internal, External or
Lesser Limit
Limit channel
Main Amplitude
(Internal)
0 to E
O
NOM
or I
O
NOM
(internal or external)
Main Channel:
Voltage (Volts) for Voltage mode,
Current (Amperes) for Current mode
Protection Limit Amplitude
(Internal)
E
O
MIN
or I
O
MIN
to
1.01 E
O
NOM
or I
O
NOM
Limit Channel, Positive and Negative
Voltage (Volts) for Current mode,
Current (Amperes) for Voltage mode
Output status ON or OFF
MISCELLANEOUS FEATURES
Digital Maximum/Mini-
mum Settings
Protection Limit
Type
Bipolar (default) or Independent
Main Channel 0 to E
O
NOM
or I
O
NOM
(default) Software limit to setting of main channel:
Voltage (Volts) for Voltage mode,
Current (Amperes) for Current mode.
Protection Limit Channel
(maximum value, Internal)
E
O
MIN
or I
O
MIN
to
1.01 E
O
NOM
or I
O
NOM
(internal)
Software limit to setting of protection limit
channel:
Voltage (Volts) for Current mode
Current (Amperes) for Voltage mode
Digital Self-test capabilities Serial Interface, Analog, Output Serial Interface test requires Loop Back Test
connector
Digital Interface Settings Data Format SCPI
Output Status @ Reset ON or OFF (OFF = default)
Serial Baud Rate Off, 9600, 19200 (Off = default)
Device Clear SCPI (default) or MATE
XON/XOFF Enable (default) or Disable
Prompt Disable (default), Enable,
Enable with Echo
Digital Calibration Computer-assisted through GPIB or
RS 232 bus
Except analog Voltage Readback with local
manual calibration.
Power-up Settings (top cover accessible
(see Table 2-2)
Allow the unit at power up to:
Set Load type
Set the GPIB address
Set the system configuration for multiple units in series or parallel.
Enable the analog programming input for main channel and for limit channels.
Enable the control signal for the mode of operation, voltage or current.
Set the unit with previously saved custom settings.
Reset the unit to internal factory default settings, after which the desired power-up
settings must be configured.
TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)
SPECIFICATION RATING/DESCRIPTION CONDITION