TABLE 1-2. BOP GENERAL SPECIFICATIONS
SPECIFICATION RATING/DESCRIPTION CONDITION
INPUT CHARACTERISTICS
A-C Voltage nominal 230 Va-c
Single phase, or between two phases of a 3-
phase system
range 176 - 264 Va-c
Frequency nominal 50-60 Hz
range 47 - 63 Hz
Current 176 Va-c 9.5A maximum
264 Va-c 6.4A maximum
Power factor
Source 0.99 minimum
nominal output power
Sink 0.97 minimum
Efficiency 65% minimum, when sourcing
Switching frequency 70 KHz PFC Stage, 5% tolerance
EMC Compliance EN61326-1 (1997) Class A equipment
EMC immunity to: ESD EN61000-4-2 Electrostatic discharge
Radiated RF EN61000-4-3
EFT EN61000-4-4 Electrical fast transient/burst
Surges EN61000-4-5
Conducted RF EN61000-4-6
EMC emissions Conducted EN61000-3-2 harmonics
EN61000-3-3 fluctuation & flicker
Conducted EN55011/CISPR11 0.15 to 30 MHz
Radiated EN55011/CISPR11 30 to 1000 MHz
Leakage current 3.5 mA 230V a-c, 60 Hz
Insulation coordination Input Installation Category II
for TN or TT power systems
Overvoltage Category II
Output Installation Category II maximum 300V (500V for BOP 10-100GL)
isolation voltage between each output termi-
nal and chassis ground.
Overvoltage Category II
Pollution degree 2
OUTPUT CHARACTERISTICS
(1)
Type of stabilizer Voltage-Current, 4 quadrant Switch mode
Switching frequency 100KHz Output Stage, 5% tolerance
Source adjustment
range
voltage -100% to +100% of rating 0 to 50 deg C
current -100% to +100% of rating
Sink adjustment range voltage -100% to +100% of rating 0 to 50 deg C. Recuperated energy is sent
back into line for general reuse.
current -100% to +100% of rating
(1) Output characteristics are for a single standalone unit.