Operator Manual Firmware Ver.3.05 and higher Instruction Manual

Table Of Contents
B-34 BOP-1KW-GL 022814
B.120 STATus:questionable:ENABle? QUERY STAT:QUES:ENAB?
Syntax: Short Form: STAT:QUES:ENAB? Long Form: STATus:QUESionable:ENABle?
Return Value: <int_value> actual register value
Description: Reads Questionable Condition Enable Register (see Table B-4). Power supply returns value of
Questionable Condition Enable Register, indicating which conditions are being monitored. Bit set to 1
= function enabled (active, true); bit reset to 0 = function disabled (inactive, false)
. Related Com-
mands: STAT:QUES?. (See example, Figure B-11.)
B.121 SYSTem:BEEP COMMAND SYST:BEEP
Syntax: Short Form: SYST:BEEP Long Form: SYSTem:BEEP
Description:Causes the unit to emit a brief audible tone
B.122 SYSTem:COMMunication:GPIB:ADDRess COMMAND SYST:COMM:GPIB:ADDR
Syntax: Short Form: SYST:COMM:GPIB:ADDR<INT VAL> 0 to 30
Long Form: SYSTem:COMMunication:GPIB:ADDRess<INT VAL> 0 to 30
Description:Sets selected power supply GPIB address. NOTE: After executing this command, subse-
quent commands must be directed to the new GPIB address. Requires MEM:UPD (PAR. B.12) to save for
power up. See PAR. 3.5.5.2 and Figure 3-6 for special programming considerations.
B.123 SYSTem:COMMunication:GPIB:ADDRess? QUERY SYST:COMM:GPIB:ADDR?
Syntax: Short Form: SYST:COMM:GPIB:ADDR?
Long Form: SYSTem:COMMunication:GPIB:ADDRess?
Return Value: <int_value> 0 to 30
Description: Identifies selected power supply GPIB address.
B.124 SYSTem:COMMunication:SERial:BAUD COMMAND SYST:COMM:SER:BAUD
Syntax: Short Form: SYST:COMM:SER:BAUD {19200 | 9600 | 4800 | 2400}
Long Form: SYSTem:COMMunication:SERial:BAUD {19200 | 9600 | 4800 | 2400}
Description: Sets the unit to operate at the specified baud rate. See PAR. 3.5.5.2 and Figure 3-6 for special pro-
gramming considerations.
B.125 SYSTem:COMMunication:SERial:BAUD? QUERY SYST:COMM:SER:BAUD?
Syntax: Short Form: SYST:COMM:SER:BAUD?
Long Form: SYSTem:COMMunication:SERial:BAUD?
Return Value: <int_value> {19200 | 9600 | 4800 | 2400}
Description: Returns operating baud rate.
B.126 SYSTem:COMMunication:SERial:ECHO COMMAND SYST:COMM:SER:ECHO
Syntax: Short Form: SYST:COMM:SER:ECHO {ON | OFF} or {01 | 00}
Long Form: SYSTem:COMMunication:SERial:ECHO {ON | OFF} or {01 | 00}
Description: Enables (ON) or disables (OFF) echo mode (see PAR. 3.6.4.2.2). Sending ON or 01 causes all sub-
sequent characters to be echoed back. Sending OFF or 00 turns off the character echo after the next
line terminator character. The *RST command has no effect on echo status. See PAR. 3.5.5.2 and Fig-
ure 3-6 for special programming considerations.
B.127 SYSTem:COMMunication:SERial:ECHO? QUERY SYST:COMM:SER:ECHO?
Syntax: Short Form: SYST:COMM:SER:ECHO?
Long Form: SYSTem:COMMunication:SERial:ECHO?
Return Value: {01 | 00}
Description: Returns 01 when echo mode is active (ON) or 00 when disabled (OFF) (see PAR. 3.6.4.2.2).