Owner's manual
Table Of Contents
- SECTION 1 - INTRODUCTION
- SECTION 2 - INSTALLATION
- SECTION 3 - CALIBRATION
- SECTION 4 - OPERATION
- FIGURE 1-1. Remotely Controlled Power Supply Configurations Using Kepco Products
- SECTION 1 - INTRODUCTION
- 1.1 Scope of Manual
- 1.2 General Description
- TABLE 1-1. Kepco BIT 488, BIT 4882, and BIT 4886 Digital Programming Cards
- TABLE 1-2. Applicability of BIT 4882, 4882-F and BIT 4886 Cards to Specific BOP Models
- 1.3 Specifications, BIT 4882, BIT 4882-F and BIT 4886
- TABLE 1-3. Specifications, BIT 4882, BIT 4882-F AND BIT 4886
- SECTION 2 - INSTALLATION
- 2.1 Unpacking and Inspection
- 2.2 Set Start-up DefaultS
- 2.2.1 Set (GPIB) Device Address
- 2.2.2 Start-up Language Default
- 2.2.3 IEEE Cable Shield Ground Selection
- 2.2.4 Set Power Supply Identification Switch
- FIGURE 2-1. BIT 4882 and BIT 4882-F Switch and Adjustment Locations
- TABLE 2-1. Power Supply Identification Switch S2 Setting
- 2.3 Installation of Interface Card into the BOP
- TABLE 2-2. Device Address Selection
- FIGURE 2-2. Installation of Model BIT 4882-f into BOP
- FIGURE 2-3. Installation of Model BIT 4882 into BOP
- 2.4 Input/OUtput Signals
- TABLE 2-3. Input/Output Pin Assignments
- FIGURE 2-4. IEEE 488 (GPIB) Connector
- SECTION 3 - CALIBRATION
- 3.1 Equipment Required
- 3.2 Adjustment of the Bop ±10 Volt Calibration Controls (R31, R32)
- 3.3 Adjustment of the Ammeter Zero (R50)
- FIGURE 3-1. BOP Power Supply, Internal Calibration Control Locations
- 3.4 Adjustment Of The Output Voltage Zero (R81)
- 3.5 Adjustment of the Full Scale Output Voltage (R21)
- TABLE 3-1. BOP Power Supply, Internal Calibration Controls
- 3.6 Voltage Reading Zero Calibration (R35)
- 3.7 Voltage Reading Calibration (R19)
- 3.8 Adjustment of the Output Current Zero (R83)
- 3.9 Adjustment of the Full Scale Output Current (R22)
- 3.10 Current Reading Zero Calibration (R36)
- TABLE 3-2. Calibration Measurements and Tolerances - Current
- TABLE 3-3. Suggested Sense Resistors
- FIGURE 3-2. Current Shunt Connections
- 3.11 Current Reading Calibration (R20)
- SECTION 4 - OPERATION
- 4.1 General
- 4.2 IEEE 488 (GPIB) Bus Protocol
- TABLE 4-1. IEEE 488 (GPIB) Bus Interface Functions
- TABLE 4-2. IEEE 488 (GPIB) Bus Command Mode Messages
- TABLE 4-3. IEEE 488 (GPIB) Bus Data Mode Messages
- 4.3 SCPI Programming
- 4.3.1 SCPI Messages
- 4.3.2 Common Commands/Queries
- 4.3.3 SCPI Subsystem Command/Query Structure
- FIGURE 4-1. Tree Diagram of SCPI Commands Used with BIT 4882, BIT 4882-F and BIT 4886 Interface Card
- 4.3.4 Program Message Structure
- TABLE 4-4. SCPI Command Index
- 4.3.4.1 Keyword
- TABLE 4-5. Rules Governing Shortform Keywords
- FIGURE 4-2. Message Structure
- 4.3.4.2 Keyword Separator
- 4.3.4.3 Query Indicator
- 4.3.4.4 Data
- 4.3.4.5 Data Separator
- 4.3.4.6 Message Unit Separator
- 4.3.4.7 Root Specifier
- 4.3.4.8 Message Terminator
- 4.3.5 Understanding The Command Structure
- 4.3.6 Program Message Syntax Summary
- 4.3.7 SCPI Program Example
- FIGURE 4-3. Typical Example of Interface Card Program Using SCPI Commands
- 4.4 CIIL Programming
- APPENDIX A - SCPI COMMON COMMAND/QUERY DEFINITIONS
- TABLE A-1. IEEE 488.2 Command/query Index
- A.2 *CLS — Clear Status Command
- A.3 *ESE — Standard Event Status Enable Command
- TABLE A-2. Standard Event Status Enable Register and Standard Event Status Register Bits
- A.4 *ESE? — Standard Event Status Enable Query
- A.5 *ESR? — Event Status Register Query
- A.6 *IDN? — Identification Query
- A.7 *OPC — Operation Complete Command
- A.8 *OPC? — Operation Complete Query
- A.9 *RST — Reset Command
- FIGURE A-1. GPIB Commands
- A.10 *SRE — Service Request Enable Command
- TABLE A-3. Service Request Enable and Status Byte Register Bits
- A.11 *SRE? — Service Request Enable Query
- A.12 *STB? — Status Byte Register Query
- A.13 *TRG — Trigger Command
- A.14 *TST? — Self Test Query
- A.15 *WAI — Wait-To-Continue Command
- APPENDIX B - SCPI COMMAND/QUERY DEFINITIONS
- B.1 Introduction
- TABLE B-1. SCPI Subsystem Command/query Index
- B.2 INITiate[:IMMediate] Command
- B.3 INITiate:CONTinuous Command
- B.4 INITiate:CONTinuous Query
- FIGURE B-1. Programming the Output
- B.5 MEASure[:SCALar]:CURRent[:DC]? Query
- B.6 MEASure:VOLTage[:SCALar][:DC]? Query
- B.7 [SOURce:]CURRent[:LEVel][:IMMediate][:AMPlitude] Command
- B.8 [SOURce:]CURRent[:LEVel][:IMMediate][:AMPlitude] Query
- B.9 [SOURce:]CURRent:[:LEVel]TRIGgered[:AMPlitude] Command
- B.10 [SOURce:]CURRent:[:LEVel]TRIGgered[:AMPlitude]? Query
- B.11 .[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude] Command
- B.12 [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude]? Query
- B.13 [SOURce:]VOLTage:[:LEVel]TRIGgered[:AMPlitude] Command
- B.14 [SOURce:]VOLTage:[:LEVel]TRIGgered[:AMPlitude]? Query
- B.15 [SOURce:]FUNCtion:MODE
- B.16 STATus:OPERation:CONDition Query
- TABLE B-2. Operation Condition Register, Operation Enable Register, and Operation Event Register ...
- B.17 STATus:OPEReration:ENABle Command
- B.18 STATus:OPEReration:ENABle? Query
- B.19 STATus:OPERation[:EVENt] Query
- B.20 STATus:PRESet Command
- B.21 STATus:QUEStionable[:EVENt]? Query
- TABLE B-3. Questionable Event Register, Questionable Condition Register and Questionable Conditio...
- B.22 STATus:QUEStionable:CONDition? Query
- FIGURE B-2. Using Status Commands and Queries
- B.23 STATus:QUEStionable:ENABle Command
- B.24 STATus:QUEStionable:ENABle? Query
- B.25 SYSTem:ERRor? Query
- TABLE B-4. Error Messages
- B.26 SYSTem:LANGuage Command
- B.27 SYSTem:VERSion Query
- FIGURE B-3. Using System Commands and Queries
- APPENDIX C - CIIL COMMAND DEFINITIONS
- TABLE C-1. CIIL Subsystem Command/query Index
- FIGURE C-1. FNC — Function Command
- FIGURE C-2. INX — Initiate Op Code Command
- FIGURE C-3. FTH — Fetch Command
- FIGURE C-4. SET Command
- FIGURE C-5. RST — Reset Command
- FIGURE C-6. CNF, IST — Confidence Test, Internal Self Test Commands
- TABLE C-2. CIIL Error Messages
- FIGURE C-7. STA — Status Command
- TABLE C-3. CIIL Error Handling Utility Commands
- FIGURE C-8. GAL — Go to alternate Language Command

C-4 BIT 4882 030507
FIGURE C-5. RST — RESET COMMAND
FIGURE C-6. CNF, IST — CONFIDENCE TEST, INTERNAL SELF TEST COMMANDS
Syntax: RST DCS :CH1
Function: This operator is used to return a power supply to its power-on state. The output voltage and current
are programmed to zero.
Example: RST DCS :CH1 The power supply is reset.
RST
Syntax: CNF or IST
Function: Causes power supply to execute confidence test.
Description: The CNF operator commands the BOP to execute the confidence test procedure defined for the BOP
power supplies (IST is functionally identical to CNF for BOP power supplies). The procedure consists
of programming voltage and current to their maximum values, checking for error flags, then program-
ming voltage and current to zero. The results of CNF are obtained through the STA command.
Example: CNF Power supply executes confidence test.
IST Power supply executes self test.
CNF, IST