Instruction Manual

BHK-MG (OPR) 022014 3-45
FIGURE 3-16. ANALOG PROGRAMMING OF OUTPUT CURRENT (CURRENT MODE) OR CURRENT
LIMIT (VOLTAGE MODE) USING HIGH IMPEDANCE, LOW LEVEL (1V) VOLTAGE SOURCE (VS)
The external voltage source is applied to the input of the uncommitted amplifier which is config-
ured as a noninverting amplifier having a gain of 10.