Instruction Manual
1-2 BHK-MG (OPR) 022014
TABLE 1-1. MODEL PARAMETERS
MODEL
NUMBER
OUTPUT
VOLTAGE
RANGE
(VOLTS)
OUTPUT
CURRENT
RANGE
(mA)
MAXIMUM
OUTPUT
POWER
(WATTS)
OUTPUT EQUIVALENT IMPEDANCE (FAST MODE)
VOLTAGE MODE
(SERIES R–L)
CURRENT MODE
(PARALLEL R–C)
R
d-c
(Ohms)
L (mH)
R
d-c
(MOhms)
C (µF)
BHK 300-0.6MG 0 - 300
0 - 600 180
0.025 2.0
3.33 0.013
0 - 60 18 33.3 0.008
BHK 500-0.4MG 0 - 500
0 - 400 200
0.0625 3.6
8.3 0.012
0 - 40 20 83 0.007
BHK 1000-0.2MG 0 - 1000
0 - 200 200
0.25 6.0
33 0.005
0 - 20 20 333 0.003
BHK 2000-0.1MG 0 - 2000
0 - 100 200
1.0 35
133 0.002
0 - 10 20 1333 0.001
TABLE 1-2. BHK-MG 200W SPECIFICATIONS
SPECIFICATION RATING/DESCRIPTION CONDITION
INPUT CHARACTERISTICS
a-c Voltage nominal (switch selectable) 115/230V a-c Single phase
range (switch selectable) 105-125/210-250V a-c
Frequency nominal 50-60Hz
range 47-63Hz
Current 115V a-c 4.0A a-c 200W at output
230V a-c 2.1A a-c
OUTPUT CHARACTERISTICS
NOTE: Current specifications contained in this table refer to source current (delivered by the unit to the load). Sink current (absorbed
by the unit from the load) occurs when the output voltage is programmed to a lower value. The sink current is constant, from
45% to 55% of High Current scale rating; it flows until the output reaches the lower voltage.
Type of Stabilizer Linear with automatic
crossover
Voltage/Current
Adjustment range
(Adjustment is either continu-
ous using analog program-
ming, or stepped using digital
programming)
Voltage 0 to 100% of rating See PAR. 1.4.2.2 and 1.4.2.3 for details
about analog programming and readback.
Use Menu program to change current
scale (See PAR 3.2.10)
Current 0-100% of rating,
or 0-10% of rating
Digital Programming
resolution
Voltage and Current 0.025% of rating Current measurement requires calibrated
shunt (see PAR. 4.2)
Digital Programming accuracy Voltage 0.025% of rating
Current 0.05% of rating Both current scales
Digital Data Readback
accuracy
Voltage 0.05% of rating
Current 0.05% of rating Both current scales, 10-100% of rating
0.005% of rating Both current scales, <10% of rating (auto-
matic 10X magnifier)
Source effect Voltage 0.001% E
O
max Input voltage
105-125/210-250V a-c
Current 0.002% I
O
max
Load effect Voltage 0.005% E
O
max no load - full load
Current 0.015% I
O
max short - full load