Owner manual

ABC 040104
B-21
7
TABLE B-4. ERROR MESSAGES
ERROR MESSAGE
ESR ERROR BIT SET
(SEE PAR. A.5)
EXPLANATION
0,“No error None No error
-100,“Command error”
Command Error bit 5
Command and data understood, but more informa-
tion included which is not recognized.
-102,”Syntax error”
Command Error bit 5
First 4 characters recognized, subsequent charac-
ters not recognized.
-103,”Invalid separator”
Command Error bit 5
For example, VOLT.PROT received instead of
VOLT:PROT
-108,”Parameter Not Allowed Error Command Error bit 5 Volt12 sequence, channel number is invalid
-109,”Missing parameter Command Error bit 5 For example, VOLT instead of VOLT 21.
-111,”Header separator error” Command Error bit 5 Missing space between volt and value or ; missing
-113,”Undefined header”
Command Error bit 5
First 4 characters could not be identified as legal
command. For example, command VLT instead of
VOLT
-120,”Numeric data error
Command Error bit 5
Expected number but other characters were
detected
-121,”Invalid character in number Command Error bit 5 Volt 1,500 ( comma not allowed)
-123,”Exponent too large” Command Error bit 5 Exponent E+3 or greater is invalid.
-141,”Invalid character data”
Command Error bit 5
For example OUTP OFD or OUTP STOP instead of
OUTP OFF
-150,”String data error”
Command Error bit 5
Invalid characters were detected in numeric entry.
For example E.1 instead of E+1 or 4d3 instead of
4.3.
-203,”Command protected” Execution error bit 4 Command only valid in password Cenable state
-221,”Settings conflict” Execution error bit 4 Invalid password from syst:pass:cen command
-222,“Data out of range” Execution error bit 4 Value exceeds power supply rating
-223,”Data format error” Execution error bit 4 Multiple decimals in digit, Multiple E, etc.
-224,“Illegal parameter value” Execution error bit 4 For example, OUTP 2 instead of OUTP 1
-241,”Hardware missing” Execution error bit 4 Requesting device 2 status (INST:NSEL 2)
-282,”Illegal program name” Execution error bit 4 Executing prog:run without LIST:SEQ command
-301,”Value bigger than limit” Device Error bit 3 Requesting a time of 301 which is bigger than limit
-311,”Memory error” Device Error bit 3 Power-up NV RAM error
-314,”Save/recall memory error Device Error bit 3 Using cell other than 1 - 41 for SAV and RCL
-341,”Non Volatile Mem. CRC error
Device Error bit 3
Power supply constants may be corrupted; recali-
bration may be necessary.
-350, “Queue overflow” Query Error bit 2 More than 15 errors are in queue.
-410,”Query interrupted”
Query Error bit 2
New command sent before data from previous
query read. Previous query data lost.
-430, “Query Deadlocked” Query Error bit 2 Over 255 characters received in single input string"