Owner manual
ABCOPR040104
1-3
OUTPUT CHARACTERISTICS (Continued)
Programming time 2ms max 0-100%
Programming
accuracy
Voltage <0.025% E
O
max
Current
0.1% I
O
max
ABC 10-10DM
ABC 15-7DM
0.05% I
O
max ABC 25-4DM
0.025% I
O
max
ABC 36-3DM
ABC 60-2DM
ABC 125-1DM
Readback/Display
accuracy
Voltage <0.05% E
O
max
Current <0.1% I
O
max
Transient recovery to
load change
Excursion <5% E
O
max
50-100% load change
return to 1% E
O
max
Recovery <200 usec
Overshoot None Turn ON/OFF
Data entry Local 24 keypads Front panel
Remote GPIB SCPI commands
GENERAL (ENVIRONMENTAL) CHARACTERISTICS
Temperature Operating 0° to +50° C No derating, 100% P
O
max
Operating +50° to +70° C Linear derating to 40% P
O
max
Storage -20° to +70° C
Humidity
0 to 95% RH
Non condensing
operating & storage
Shock 20g, 11msec ±50%
half sine
3-axes
3 shocks each axis
Vibration 5-10Hz 10mm
double amplitude
Non operating
1 hour each axis
Altitude Sea level to 10,000 feet
Cooling Natural convection
PHYSICAL CHARACTERISTICS
Dimensions English 7.9” x 4.9” x 14” ±1/32”
See Outline Drawing, Figure 1-1.
For rack mounting see
Figures 1-2 and 1-3.
Metric 200.8 x 124.6 x 355.6 mm
±0.8 mm
Weight English 11 lbs.
Unpacked
Metric 5 Kg
A-C input
connections
Front Panel ON/OFF switch
Rear Detachable IEC 320 type
connector
3 wire fused
Output
connections
Front 5 binding posts
±Output, ±Sense, Ground
Rear 5 terminal barrier strips
Remote control
programming
One standard
GPIB connector
Rear,
SCPI & IEEE 488.2 Commands
Digital display
front panel
Voltage, current, mode,
status, menu, program,
etc.
2 x 16 character alphanumeric
LCD with LED backlight
TABLE 1-3. ABC SPECIFICATIONS (Continued)
SPECIFICATION RATING/DESCRIPTION
CONDITION