Installation guide

STEP
2:
PREPARE
THE
VENTING
SYSTEM
STANDARD
FITTINGS
NOTE:
If
the
existing
duct
is
round,
you
must
use
a
rectangular-to-round
adapter,
with
a
rectangular
3"
extension
duct
installed
between
the
damper
assembly
and
the
adapter
to
prevent
the
exhaust
damper
sticking.
DUCT
LENGTH
The
total
length
of
the
duct
system,
including
straight
duct,
elbows,
transitions, wall
or
roof
caps
must
not
exceed
the
equivalent
of
140
feet.
For
best
performance,
do
not
use
more
than
three
90
degree
elbows,
and
keep
length
as
short
as
possible.
Below
are
the
standard
fittings
and
their
equivalent
length
in
feet.
gu
Pa
<<)
©
Ce
i
Qe
ry
+
3-1
/4"x10"
to
6"
=
5ft.
3-1/4"x10"
roof
cap
=
24ft.
3-1/4"x10"
90°
elbow
=
25ft.
oS
Ss
2
90°
elbow
=
10ft.
3-1
/4"x10"
wall
cap
=
40ft.
45°
elbow
=
5ft.
3-1/4"x10"
flat
elbow
=
1
Off.
Figure
10
To
calculate
the
equivalent
length
of
each
duct
piece
used,
see
the
examples
below.
I
Examples
For
3-1/4"x10"
SYSTEMS
For
6"
ROUND
SYSTEMS
je
6ff.
——»|_-
Wall
cap
90°
elbows
fa——
ft,
——»
/
“yf
K
Wall
cap
3-1/4"x10"
t
90°
elbow
ait
Transition
13-1/4"
x
10"
90°
elbow
==
25
ft.
1
transition
=
5
ft.
1
wall
cap
=
AO
fi.
2
90°
elbows
=
20
ft.
8
feet
straight
duct
=
8
ft.
1
wall
cap
=
AO
ft.
TOTAL
LENGTH
=
73
ft.
8
feet
straight
=
8
ft.
TOTAL
LENGTH
=
73
ft.