Models/Modelos | 721.80032 721.80033 ||NSTALLATION INSTRUCTIONS INSTRUCCIONES DE INSTALACION 721.80034 721.80039 721.80042 I — | > SS 721.80043 P) 721.80044 721.80049 721.81043 721.85032 721.85033 721.85039 —— es = Wes a | ¢ — - EE TONVdS4 SS, Read and save these installation instructions. Microwave Hood Combination Lea y guarde estas Combinacién Microondas Campana instrucciones de instalacién Part No. MFL39433001 Sears, Roebuck and Co., Hoffman Estates, IL 60179 www.sears.
YOUR SAFETY FIRST BEFORE YOU START * Proper installation is the installer's responsibility! - Read the entire manual before you begin. - The model number label is located on the oven front. See Figure 1. - Mounting plate is located on back side of microwave oven. See Figure 2. BE SURE TO READ THE FOLLOWING Model SAFETY INSTRUCTIONS: Number Label Mounting Plate Ae 2aa () Z ve Figure | Figure 2 A WARNING & FOR YOUR SAFETY: * You will need TWO people to install this oven.
YOUR SAFETY FIRST ¢ THIS APPLIANCE MUST BE GROUNDED! - If there is an electrical short circuit, grounding reduces the risk of electrical shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. PROPERLY POLARIZED AND * Place the plug into a properly installed and grounded ouilet. See Figure 3. ©£GROUNDED OUTLET * Do not use an extension cord. * Keep the power cord dry and do not pinch or crush ft.
YOUR SAFETY FIRST ¢ MAKE SURE YOU HAVE ENOUGH SPACE AND SUPPORT. - Mount the oven against a flat, vertical wall, so that it is supported by the wall. The wall should be constructed of minimum 2" x 4" wood studding and 3/8" thick drywall or plaster /lath. - ATTACH AT LEAST ONE of the two lag screws supporting the oven to a vertical, 2" x 4" wall stud. - DO NOT mount the microwave oven to an island or peninsula cabinet. - BE SURE the upper cabinet and rear wall structures are able to support 150 Ibs.
PARTS, TOOLS, MATERIALS THE FOLLOWING PARTS ARE SUPPLIED WITH THE OVEN: NOTE: Depending on your ventilation requirements, you may not use all of these parts. Damper/duct connector One power cord clamp and (for roof vented or wall vented installation). Not Actual Size One dark-colored mounting screw (to hold the power cord). Actual Size © Om | One power cord clamp bushing - Actual Size (for the cord hole in a metal upper cabinet).
PARTS, TOOLS, MATERIALS YOU WILL NEED THE FOLLOWING TOOLS AND MATERIALS FOR THEINSTALLATION: Carton or other heavy material for covering the counter top. Clear tape Stud finder or thin nail. (for taping the templates to the wall). AE = SE Saber saw (for cutting vent holes for roof or wall venting). Key hole saw (for the power cord hole). Ae 2aa () Z ve Phillips screwdriver (for the screws). —— eS) 3/8" and 3/4" wood drill bits Pencil Flat blade screwdriver (for the bolts).
STEP 1: PREPARE THE ELECTRICAL CONNECTIONS A WARNING & AVOID ELECTRICAL SHOCK! THIS APPLIANCE MUST BE GROUNDED! 1. Locate the grounded electric outlet for this oven in the cabinet above the oven, as shown in Figure 4 Detail. Upper Cabinet NOTE: The outlet should be on a circuit dedicated to the microwave oven | 20V, 60Hz., AC only, with a 20ampere fused electrical supply. Grounded Qutlet IMPORTANT: If you do not have the proper wall outlet, you MUST have one installed by a qualified electrician.
STEP 2: PREPARE THE VENTING SYSTEM NOTE: The ductwork you need for outside ventilation is not included with your oven. The standard ductwork fittings and length are shown in Figure 9, page 9. Aw WARNING-FIRE HAZARD 4& THIS OVEN MUST BE PROPERLY VENTED! You may vent your oven in one of three ways: Roof Venting: If your oven is located on an outside wall near the roof, as in Figure 6 (3-1 /4" x 10" duct) and Figure 8 (6" round duct.
STEP 2: PREPARE THE VENTING SYSTEM STANDARD FITTINGS NOTE: If the existing duct is round, you must use a rectangular-to-round adapter, with a rectangular 3" extension duct installed between the damper assembly and the adapter to prevent the exhaust damper sticking. DUCT LENGTH The total length of the duct system, including straight duct, elbows, transitions, wall or roof caps must not exceed the equivalent of 140 feet. For best performance, do not use more than three 90 degree elbows.
STEP 3: PREPARE THE VENTING BLOWER Your microwave oven is shipped with the blower assembled for room venting (recirculating). You need to adjust the blower if you want wall vented or roof vented installation. A WARNING A ELECTRICAL SHOCK HAZARD! UNPLUG DO NOT PULL OR STRETCH THE BLOWER in electrical shock. WIRING! UNIT BEFORE WORKING ON IT. Pulling and stretching the blower wiring could result . Remove any shipping materials and parts from inside the microwave oven.
STEP 3: PREPARE THE VENTING BLOWER WALL VENTED INSTALLATION 1. Remove one blower unit mounting screw and two blower plate screws. Remove the blower plate Back plate Blower unit from cabinet. See Figure 12. _- Blower plate 2. Carefully lift the blower unit out of the microwave i mounting screws oven. Disconnect the blower wire from connector. See Figure 13. 3. Use side cutters or tin snips to cut and remove knockouts "B"from Back plate. Discard knockouts.
STEP 3: PREPARE THE VENTING BLOWER ROOF VENTED INSTALLATION 1. Remove one blower unit mounting screw and two blower plate screws. Remove the blower plate from cabinet. See Figure 18. (| Blower plate 2. Carefully lift the blower unit out of the microwave oven. 3. Rotate blower unit 90° so the exhaust ports face the top of the cabinet. See Figure 19. Blower P 4. Place blower unit back into microwave oven. Ae 2aa Figure i Blower unit mounting screws 18 5.
STEP 4: PREPARE THE WALL AND UPPER CABINET FOR INSTALLATION MEASURE AND TACK / TAPE UP THETEMPLATE 1. Using a plumb line and (metal) measuring tape, find. and mark the vertical center line (Yon the back wall, as in Figure 22. 2. Find and mark one or two points where the studs are on the wall (Studs are normally 16 inches apart). and then measure and mark the stud locations. If you cannot find any wall stud, consult a local building contractor. —— £& CAUTION £4 —— 3.
STEP 4: PREPARE THE WALL AND UPPER CABINET FOR INSTALLATION DRILL THE HOLES IN THE WALL AND UPPER CABINET. A WARNING AA BE VERY CAREFUL WHEN DRILLING HOLES INTO THE WALL. Electrical wires could be concealed behind the wall covering and if the drill hits them you could get an electric shock. 1. Find the points on the mounting plate labeled "A", "B","C"and "D". Drill a 3/16" diameter hole at any of these points that are in front of a wall stud.
STEP 5: INSTALL THE MOUNTING PLATE TO THE WALL THE OVEN MUST BE CONNECTED TO AT LEAST ONE WALL STUD ]. Draw a vertical line on the wall at the center of the 30" wide space. 3/16" Hole on Studs 3/4" Hole on Dry wall Only Minimum 66" From the Floor For WallVented Only Use the mounting plate as the template for the rear wall. Place the mounting plate on the wall, making sure that the tabs are against the bottom of the cabinet.
STEP 5: INSTALL THE MOUNTING PLATE TO THE WALL TO PREPARE THE REAR WALL CUTOUT OPENING AND EXHAUST ADAPTOR/ MOUNTING PLATE FOR WALL VENTING AND ROOF VENTING: NOTE: If room vented installation is used, skip this step. * « * a . c 1. Using the Wall-template. This template will give the location and F CUT OUT FOR WALL VENTED ONLY size of the box cutout for the rear wall duct as described in step 5 item I(page 15) . Using a pencil, put dots through slots "F"and "G", and through holes "H" and "I".
STEP 6 : ATTACH THE OVEN TO THE WALL —_— £§ WARNING & —— You will need two people to lift this microwave. Failure to use more than one person could result in personal injury. Power cord Power cord . Carefully lift microwave oven and hang if on S . Rotate the microwave oven upward so the top of even is against the bottom of the upper cabinet or cabinet frame. aS) ECO) ye support tabs (See Figure 26) at the bottom of the mounting plate.
STEP 6 : ATTACH THE OVEN TO THE WALL . Roof vented installation: See Figure 32. Install ductwork through the vent opening in the upper cabinet. Complete the venting system through the roof according to the method needed. See “PREPARE THE VENTING SYSTEM,” STEP 2 on the page 8. Use caulking fo sealexterior roof opening around the exhaust cap. See Figure 6 on page 8. . Use power supply cord clamp to bundle the power Damper J EE | Figure 32 supply cord.
Printed in china