GAS COOKTOP INSTALLATION INSTRUCTIONS
4
2
Provide an Adequate Gas Supply
This cooktop is designed to operate on natural gas at 4"
of manifold pressure only.
A pressure regulator must be connected
in series with the manifold on the cooktop and must
remain in series with the supply line.
For proper operation, the maximum inlet pressure to the
regulator must be no more than 14" of water column
(W.C.) pressure.
For checking the regulator, the inlet pressure must be at
least 1" (or 2.5 kPa) greater than the regulator manifold
pressure setting. The regulator is set for 4" of manifold
pressure, the inlet pressure must be at least 5".
The gas supply line to the range should be 1/2" or 3/4"
pipe.
1
Wall Outlet Location
Figure 3A - 36” MODEL
ELECTRICAL OUTLET INSTALL DIMENSIONS
Figure 3B - 30” MODEL
ELECTRICAL OUTLET INSTALL DIMENSIONS
Install the electric wall outlet within the shaded area.
6”
(15.2 cm)
4”
(10.2 cm)
11
1
/2
(29.2 cm)
5
1
/2
(13.9 cm)
8
3
/4
(22.2 cm)
3
1
/4
(8.3 cm)
4”
(10.2 cm)
5
1
/2
(13.9 cm)
11”
(27.9 cm)
4”
(10.2 cm)
Recommended
Gas Supply
Stub Area
Recommended
Gas Supply
Stub Area
Required Tools for Installation
- Phillips Screwdriver
- ¼" Nut driver / Ratchet
-
7
/
16" Nut driver / Ratchet
Supplied Hardware
(4)
1/4-20 Nylon Insert
7/16" Hex Nut
#8-18 Wide Head
Phillips Screw
#8-18 Black
¼" Hex Head Screw
Hold Down Bracket
#10-24 3.5"
Long Phillips Screw
Blower (g. 20)
Brackets
(g. 15 & 16)
Transition Duct
(g. 18)
Plenum and Wire
Box (g. 17 & 21)
Countertop
(g. 15 & 16)
Qty. Description Used for
(2)
(4)
(6)
(2)