Installation Guide

GAS COOKTOP INSTALLATION INSTRUCTIONS
14
DUCT PIECES
EQUIVALENT
LENGTH X
NUMBER
USED =
EQUIVALENT
LENGTH
6" (15.2cm) Round
Straight **
1 Ft. (0.3m) Ft. or m
6" (15.2cm) Round Metal Flex
No Bends **
1.5 Ft. (0.45m) Ft. or m
6" (15.2cm)
90° Elbow
10 Ft. (3m) Ft. or m
6" (15.2cm)
45° Elbow
5 Ft. (1.5m) Ft. or m
3¼" x 10" (8.2cm x 25.4cm)
Straight **
1 Ft. (0.3m) Ft. or m
3¼" x 10" (8.2cm x 25.4cm)
90° Elbow
10 Ft. (3m) Ft. or m
3¼" x 10" (8.2cm x 25.4cm)
45° Elbow
5 Ft. (1.5m) Ft. or m
3¼" x 10" (8.2cm x 25.4cm)
90° Flat Elbow
10 Ft. (3m) Ft. or m
3¼" x 10" (8.2cm x 25.4cm)
to 6" (15.2cm) Round Transition
90° Elbow
30 Ft. (9m) Ft. or m
6" (15.2cm) Round to 3¼" x 10"
(8.2cm x 25.4cm) Transition
90° Elbow
30 Ft. (9m) Ft. or m
3¼" x 10" (8.2cm x 25.4cm) to
6" (15.2cm) Round Transition
5 Ft. (1.5m) Ft. or m
6" (15.2cm) Round to 3¼" x 10"
(8.2cm x 25.4cm) Transition
5 Ft. (1.5m) Ft. or m
6" (15.2cm) Round Wall Cap
with Damper
30 Ft. (9m) Ft. or m
3¼" x 10" (8.2cm x 25.4cm)
Wall Cap with Damper
30 Ft. (9m) Ft. or m
6" (15.2cm) Round Roof Cap 30 Ft. (9m) Ft. or m
TOTAL DUCTWORK Ft. or m
** For Straight Round / Rectangular Duct, measure actual linear
feet used and then multiply by Equivalent Length shown.
Calculating Duct Length Table
For maximum eciency, use the shortest and straightest duct possible. Use as few ttings as
possible. For best performance, the duct run should not exceed 100 feet of equivalent length.