Manual
16
WARNING: Risk of electric shock. Electrical
wiring must be done by qualifi ed personnel
in accordance with all applicable codes and
standards. Before connecting wires, switch
power off at service panel and lock service
disconnecting means to prevent power from
being switched on accidentally.
1. Connect House Power Cable to range hood wiring:
BLACK to BLACK, WHITE to WHITE and GREEN or
bare wire under GREEN ground screw.
2. Reinstall the blower cover plate (shaded part on
illustration beside) using the lock nut and7screws
previously removed in step 3 on page 9. Pay attention
to screw 1 location; from back of hood point of view, it
must be located on left side of the lock nut (see inset).
CONNECT THE WIRING
MOTORS
GROUND
WIRE
HOUSE
POWER
CABLE
GROUND
SCREW
Ducted Installation Only:
Re-install grease fi lters removed in step 2 on page 8,
under “Prepare the Hood”.
INSTALL THE FILTERS
“Non-ducted Filters” available by calling Sears at
1-800-4-MY-HOME
®
Non-ducted Installation Only:
Purchase two non-ducted fi lters (see part number in
Service parts list). Attach the non-ducted fi lters following
instructions packed with the non-ducted fi lters.
1
2
3
45
6
7
BACK OF HOOD
LOCK NUT
1