User guide

Page 22
Press / Action Display Description
and simultaneously
Enter the Program Menu
One Time
Cycle to Program #00
For Example:
Indicates the flow measurement version
(selected in Pr.21). Gallons per Minute (GPM)
shown.
Displays the last saved flow measurement
value. The first digit is flashing.
or
Enter the “Style” (X) number of the desired
flume or weir type (see the following section on
Flume / Weir Styles and Dimensions)
Last two digits are flashing.
Enter the specific flume / weir (FF)dimension
code (see the following section on Flume / Weir
Styles and Dimensions).
Selected values are saved.
Returns to Pr.00
Flume / Weir Styles and Dimensions
Using Pr.00 program, The data is entered in the following format: , where:
X = Flume / Weir Style
U = U.S. Standard (U) or European (E) type flume / weir
FF = The specific flume / weir dimensions
The U.S. or European types are selected in Pr.22 (see Initial Set-up Programs). The following pages show the flumes
weirs by Style (X) and Dimensions (FF).
Code
(X)
U.S Standard (Page #) European (Page #)
1
Rectangular Suppressed Sharp-Crested Weir (23) Rectangular Suppressed Sharp-Crested Weir (26)
2
Rectangular Contracted Sharp-Crested Weir (23) Rectangular Contracted Sharp-Crested Weir (26)
3
Trapezoidal (Cipolletti) Sharp-Crested Weir (23) Trapezoidal (Cipolletti) Sharp-Crested Weir 26()
4
V-notch (Triangular) Sharp-Crested Weir (24) V-notch (Triangular) Sharp-Crested Weir (27)
5
Parshall Flume (24) Khafagi-Venturi Flume (27)
6
Palmer-Bowlus Flume (24) Parshall Flume (27)
7
H-Flume (25) Palmer-Bowlus Flume (28)
8
Leopold-Lagco Flume (25) H-Flume (28)
9
NONE Neyrpic-Venturi Flume / Long Base Weir (28)