10.12 Connecting the pneumatic system
For the supply, a compressed-air hose with a min. internal diameter of 6 mm is required;
it is fastened to the housing by means of a screw connection (not included in the
delivery). A compressed-air shuto valve in the supply line is recommended. This allows
the Robot Gun Cleaning Station to be depressurized quickly and simply, for carrying
out any installation and maintenance work.
Figure 22: Connecting the pneumatic system