Operation Manual
13
Robot Gun Cleaning Station© Kemppi Oy 2016 1616
OPERATING MANUAL
10. INSTALLING THE ROBOT GUN
CLEANING STATION
This section describes how to install the Robot Gun
Cleaning Station unit.
Risk of injury due to unexpected start-up
For the entire duration of maintenance, servicing,
unmounting, and repair work, the following instructions
must be adhered to:
• Switch o the power supply.
• Cut o the compressed air supply.
• Pull the power plug.
The parts of the system are depicted in the gure below.
Proceed as follows:
1. Connect the two hoses (4 and 8) to the applicable
bottles to put the injection unit of the welding
torch into operation.
All other connections for compressed air are pre-mounted
at the factory.
Ensure that the non-return valve (6) is attached to the
suction hose (4).
2. Connect the device through the compressed-air
hose.
Figure 7: Installing the Robot Gun Cleaning Station
1. Return connection (pre-mounted)
2. Setting for the amount of suction air
3. Connection of anti-spatter system to injection unit
4. Suction hose
5. Anti-spatter bottle (full)
6. Non-return valve
7. Anti-spatter drain bottle
8. Hose
9. Compressed-air connection (pre-mounted)
10. Suction connection (pre-mounted)