Operation Manual

EN
Welding process selector, MMA / TIG
Switch is used for selecting either MMA or TIG welding, depending on
welding target.
VRD: When you have switched the unit to TIG welding, VRD is constantly
active, thus reducing terminal voltage to 30 V. This facilitates arc cut-o when
you stop welding.
Regulating welding current
Welding current rate is regulated steplessly with an adjusting potentiometer.
Signal light for overheating
A yellow signal light of overheating is lit, when thermostat has tripped due
to the unit’s overheating. Fan will cool the unit and after the signal light goes
o, the unit is again ready for welding.
3.3 WELDING SELECTIONS
3.3.1 Manual Metal Arc welding (MMA)
Select welding parameters according to ller manufacturers
recommendations.
1. Select polarity (+ or -) of welding current cable and return current cable
according to ller.
2. Select MMA welding with the switch
.
3. Select suitable welding current by adjusting potentiometer.
3.3.2 DC TIG welding
Select welding parameters according to ller manufacturers
recommendations.
1. Connect TIG torch to - pole and earth cable to + pole
2. Select TIG welding with the switch
.
3. Select suitable welding current by adjusting potentiometer.
9
Minarc 150, 151 / © Kemppi Oy / 1117