Instruction Manual
Table Of Contents
- 1. General
- 2. Installation
- 2.1 Installing power source mains plug
- 2.2 Installing cooling unit (optional)
- 2.3 Installing equipment on cart (optional)
- 2.4 Connecting welding gun
- 2.5 Installing earth return cable
- 2.6 Installing remote control (optional)
- 2.7 Installing and replacing feed rolls
- 2.8 Installing and replacing wire guide tubes
- 2.9 Installing and changing wire
- 2.10 Installing gas bottle and testing gas flow
- 2.11 How to get welding programs
- 3. Operation
- 3.1 Preparing welding system for use
- 3.2 Calibrating welding cable
- 3.3 Using control panel
- 3.3.1 Control panel: Home view
- 3.3.2 Control panel: Weld Assist
- 3.3.3 Control panel: Channels
- 3.3.4 Control panel: WPS view
- 3.3.5 Control panel: Welding parameters
- 3.3.6 Control panel: Weld history
- 3.3.7 Control panel: Info view
- 3.3.8 Control panel: Device settings
- 3.3.9 Control panel: Applying welding programs
- 3.3.10 Control panel: Weld data view
- 3.4 Additional guidance to functions and features
- 3.5 Pulse welding
- 3.6 Wireless connection (WLAN)
- 3.7 Using remote control
- 3.8 Changing welding polarity
- 3.9 Lifting equipment
- 4. Maintenance
- 5. Technical data
Master M 358
Operating manual - EN
5.2 Master M cooling unit
Master M Cooler
Master M Cooler
Feature Value
Supply voltage
U
1
380...460 V +/- 10 %
Maximum supply current @ 380...460 V
I
1max
0.7 A
Cooling power @ 1 l/min
1.0 kW
Recommended coolant
MGP 4456 (Kemppi mixture)
Maximum coolant pressure
0.4 MPa
Tank volume
3 l
Operating temperature
range
With recommended coolant
-20...+40 °C
Storage temperature range
-40...+60 °C
EMC class
A
Degree of protection When mounted
IP23S
Package external dimensions
L
x
W
x
H
635 x 305 x 292 mm
Weight Without accessories
14.9 kg
Standards
IEC 60974-2, -10
Master M Cooler MV
Master M Cooler MV
Feature Value
Supply voltage
U
1
220...240 V +/- 10 %
380...460 V +/- 10 %
Maximum supply current @ 220...230 V
I
1max
1.0 A
@ 380...460 V
I
1max
0.7 A
Cooling power @ 1 l/min
1.0 kW
Recommended coolant
MGP 4456 (Kemppi mixture)
Maximum coolant pressure
0.4 MPa
Tank volume
3 l
Operating temperature
range
With recommended coolant
-20...+40 °C
Storage temperature range
-40...+60 °C
EMC class
A
Degree of protection When mounted
IP23S
Package external dimensions
L
x
W
x
H
635 x 305 x 292 mm
Weight Without accessories
14.9 kg
Standards
IEC 60974-2, -10
© Kemppi
86