Instruction Manual
Table Of Contents
- 1. General
- 2. Installation
- 2.1 Installing power source mains plug
- 2.2 Installing cooling unit (optional)
- 2.3 Installing equipment on cart (optional)
- 2.4 Connecting welding gun
- 2.5 Installing earth return cable
- 2.6 Installing remote control (optional)
- 2.7 Installing and replacing feed rolls
- 2.8 Installing and replacing wire guide tubes
- 2.9 Installing and changing wire
- 2.10 Installing gas bottle and testing gas flow
- 2.11 How to get welding programs
- 3. Operation
- 3.1 Preparing welding system for use
- 3.2 Calibrating welding cable
- 3.3 Using control panel
- 3.3.1 Control panel: Home view
- 3.3.2 Control panel: Weld Assist
- 3.3.3 Control panel: Channels
- 3.3.4 Control panel: WPS view
- 3.3.5 Control panel: Welding parameters
- 3.3.6 Control panel: Weld history
- 3.3.7 Control panel: Info view
- 3.3.8 Control panel: Device settings
- 3.3.9 Control panel: Applying welding programs
- 3.3.10 Control panel: Weld data view
- 3.4 Additional guidance to functions and features
- 3.5 Pulse welding
- 3.6 Wireless connection (WLAN)
- 3.7 Using remote control
- 3.8 Changing welding polarity
- 3.9 Lifting equipment
- 4. Maintenance
- 5. Technical data
Master M 358
Operating manual - EN
40
VRD error Open circuit voltage exceeds the VRD limit. Restart the power source. If problem persists, contact
Kemppi service.
42
High current in
wire feeder
motor
There may be too much pressure in the
wire feed rolls or dirt in the wire line.
Adjust the feed roll pressure. Clean the wire line.
Change worn parts in the welding gun.
43
Overcurrent in
wire feeder
motor
There may be too much pressure in the
wire feed rolls or dirt in the wire line.
Adjust the feed roll pressure. Clean the wire line.
Change worn parts in the welding gun.
44
Wire speed
measurement is
missing
Faulty sensor or wiring in wire feeder. Restart the welding system. If problem persists, con-
tact Kemppi service.
45
Low gas pres-
sure
Shielding gas pressure is too low. Check and adjust the shielding gas flow.
61
Operation is not
allowed
Subfeeder is connected, but it has not been
selected in the system settings.
Go to the system settings menu on the control panel
and select your subfeeder model and type.
65
Subfeeder not
allowed
Use of subfeeder is not allowed with selec-
ted welding process.
Remove the subfeeder or change the welding pro-
cess.
244
Internal memory
failure
Initialization failed (%sub:%device). Restart welding system. If problem persists, contact
Kemppi service.
250
Internal memory
failure
Memory communication failed (%sub-
:%device).
Restart welding system. If problem persists, contact
Kemppi service.