Instruction Manual

Table Of Contents
Master M 358
Operating manual - EN
Remote control
OFF/Remote/Gun
Default = OFF
If remote controller is not connected, this
selection is not available.
Remote mode
(with 1-knob remote control)
Wire feed speed / Channel This determines what is changed with
the remote, wire feed speed or memory
channel (available channels:1...5). If
remote controller is not connected and
remote not selected, this selection is not
available.
Remote mode
(with 2-knob remote control)
Welding parameter / Channel This determines what is changed with
the remote, welding parameter(s) or
memory channel (available
channels:1...5). The adjusted parameters
are process-specific.
If remote controller is not connected and
remote not selected, this selection is not
available.
Note:When the remote mode is set to
'Channel', only the left remote control
knob is in use.
Subfeeder
(with MIG only)
Subfeeder model / None
Default = None
If a compatible subfeeder is connected,
select the subfeeder from the list.
Compatible subfeeders:
SuperSnake GTX (10 m, 15 m, 20 m, 25 m),
Binzel PP401D, Binzel PP36D.
Safe wire inch
(with MIG only)
OFF/ON When ON, and the arc doesn't ignite, the
filler wire is fed 5 cm When OFF, 5 m of
filler wire is fed.
Wire retract
OFF/ON This is an automatic wire retract feature.
Once the arc is extinguished, the wire is
retracted for additional safety. The user
can change the wire retract delay and
length settings.
Note: Wire retract function is disabled if a
subfeeder is connected.
- Wire retract delay
2...10 s, step 1
Default = 5 s
- Wire retract length
1...10 cm, step 1
Default = 2 cm
Gas guard
OFF/ON
Default = OFF
Gas guard prevents welding without
shielding gas.
Language
Available languages This allows the user to select the control
panel language from a list of available lan-
guages.
Weld data time
0...30 s, step 1
0 = OFF
Default = 5 s
This defines if and how long the weld
data summary is shown after each weld.
© Kemppi
52
1921980 / 2242