Instruction Manual

Table Of Contents
Master M 358
Operating manual - EN
The amount of available memory channels differs between different operation modes: MIG (100 channels), TIG (10 chan-
nels) and MMA (10 channels).
The operation mode set in the control panel Settings determines for which main welding process the memory chan-
nels are shown.
Changing memory channel
Turn the right control knob to highlight the desired memory channel. The highlighted memory channel is automatically
activated.
Managing memory channels
The memory channels are managed through the Actions menu.
1. Enter the actions menu by pressing the right control knob.
2. Turn the control knob to highlight the desired action.
3. Select the action by pressing the right control knob.
4. Make further selections as required.
Available actions are:
Save changes: Save changes to the currently selected channel
Save to...: Save the current settings to another channel
Delete:Delete the currently selected channel
Link to WPS: Link the currently selected channel to a weld pass on a digital welding procedure specification
(dWPS) document.
Create channel:Create a new channel based on the welding program(s)
>> MIG only:Welding programs can be filtered by base material, wire material, wire diameter, shielding gas and
process. For more information, refer to "Control panel: Applying welding programs" on page53.
Create from programs:Create new channels based on all of the unused welding programs available (in MIG mode
only)
Delete all:Delete all channels.
The skewed channel number in the top left corner of the channel selection indicates that the set welding parameters are
different from the ones currently saved on the active memory channel:
© Kemppi