Operation Manual
EN
Specifying the SETUP settings for additional features
To set the values of the functional parameters for additional MIG features, use either the
SETUP feature in the control panel (see 2.2.12 "SETUP functions in the control panel") or the
QUICK SETUP feature, which you can activate by pressing the QUICK SETUP button, P8.
Select the parameter to adjust using the left-hand side control knob P11 or the button P10
and then set the parameter value with the right-hand side control know P13. The value
you specied is instantly stored in the control panel memory. The following table lists the
parameter values that can be specied for additional MIG features.
Name of
parameter
Name
displayed
Parameter values Factory setting Description
Creep Start Level
Cre 10 ... 170 % 50 % Percent of wire feed
speed default
10% refers to slow start,
170% refers to fast start
Hot Start Level
Hot -50 ... 75 % 30 % Percent of welding power:
-50% refers to cold start
+75% refers to hot start
Hot Start Time
H2t 0 ... 9.9 s 1.2 s The duration of the hot start in
seconds.
Crater Fill Start
Level
CrS 10 ... 90 % 90 % The welding power at the
beginning of the crater ll stage as
a percentage of the welding power
preset value.
Crater Fill End
Level
CrL 10 ... 90 % 30 % The welding power at the end of
the crater ll stage as a percentage
of the welding power preset value.
Crater Fill Time
Crt 0 ... 9.9 s 2 s The duration of the crater ll stage
in seconds.
NOTE! In crater ll, the initial value of the welding power must be greater than the nal value,
and therefore the adjustment ranges for the initial and nal values are restricted automatically, if
necessary.
Welding Level
Crater Fill Start Level
Crater Fill Time
Crater Fill End Level
11