Operation Manual
EN
WiseThin, Fe group
903 1,0 Fe Ar+18%-25%CO
904 1,2 Fe Ar+18%-25%CO
913 1,0 Fe CO
²
914 1,2 Fe CO
²
WiseThin, SS group
923 1,0 SS-316 Ar+2%CO
924 1,2 SS-316 Ar+2%CO
933 1,0 SS-316 Ar+30%He+1%O
934 1,2 SS-316 Ar+30%He+1%O
Using the welding program
5. Select the welding process 1-MIG with the P9 button.
6. Press the SYNERGIC PROGRAM button to display the material group and the welding
program number. Make sure that the welding program corresponds to the ller wire and
shield gas you use.
7. Check the wire type and shield gas for the welding program in the table below.
8. Adjust the welding power with the left-hand side knob and the arc length with the right-
hand side knob.
2.2.12 SETUP features of the control panel
The machine has a number of additional features, or parameters, whose settings can be
specied with the control panel's SETUP function as follows:
1. Press and hold down the SETUP button P10 for at least 5 seconds.
2. Select the parameter to adjust using the left-hand side control knob. The parameter
name is shown in display 2.
3. Specify the parameter value with the right-hand side control knob. The selected value is
shown in the display P6. The parameter’s value is immediately stored in the memory.
4. You can exit the SETUP mode by pressing and holding down the SETUP button again for
at least 5 seconds or by briey pressing the ESC button.
All welding processes have their own SETUP parameters. For example, adjusting the post-
current for synergetic MIG welding does not aect the post-current of normal MIG welding.
The tables below show the additional features available in this welding machine and their
possible values.
Normal MIG welding parameters and their values
Name of
parameter
Name
displayed
Parameter
values
Factory setting Description
Pre Gas Time PrG 0.0 ... 9.9 s 0.0 s Pre-gas time 0 ... 9.9 s.
Post Gas Time PoG Aut, 0.1 ... 32.0 s 1,0 Post gas time,
Aut = Automatic, depending on welding
current 0.1 ... 32 s
Creep Start Level Cre 10 ... 170% 50 % Percentage of wire feed speed, 10% refers
to slow start, 170% to accelerated start
Post Current Time PoC -9 ... +9 0 Post-welding current time
15
KempArc SYN 300, 400, 500, DT 400 / © Kemppi Oy / 1117