Operation Manual
17
© Kemppi Oy / 1515
EN
Crater 4T Timer
On, OFF Factory setting is OFF ON: if 4T is selected, crater lling will last
at least time that has been adjusted by
CraterTime or as long as trigger is pressed.
OFF: if 4T is selected, crater lling will last
as long as trigger is pressed.
Creep Start
10…99 % Step: 1
OFF, CURVE (OFF=100%)
Factory setting is CURVE
CURVE means that the creep start value
comes from welding program.
StartPower
-9…+9 Factory setting is 0 Adjusts arc ignition.
ADVANCED FUNCTIONS
WisePenet
ON, OFF Penetration control selection
Penet%(123A)
-30…+30 % Factory setting: 0 % WisePenetration percent setting. Set
penetration current.
WiseFusion
ON, OFF WiseFusion selection
WiseFusion%
10…60 % or
CURVE
Factory setting is CURVE When WiseFusion is ON, it controls the
amount of short circuits in the arc. The
lower the value, the less short circuits in
the arc, and the higher the value, the more
short circuits in the arc.
MatchFunc *
Minilog, MatchCh
OFF
Default is OFF Selects the type of function for toggling
between two sets of welding parameters
during welding:
Minilog=percentage of base current
MatchCh=alternative memory channel
MinilogLevel
-99…+125 % Factory setting is 20 Sets the alternative current level to a
percentage of the base current
MatchMemChannel
0…9 Factory setting is 0 Sets the pre-dened memory channel,
where the alternative set of parameters is
stored
* MatchFunc is a function that allows you to use two pre-dened sets of welding parameters
during welding. You can toggle between these parameter sets by pressing the welding gun
trigger briey without having to stop welding.
SYSTEM CONFIG MENU
Water Cooling
ON, OFF, AUTO Factory setting is AUTO Water cooler control.
ON: Water cooler is always ON
OFF: Water cooler is always OFF
AUTO: Water cooler starts when welding
starts and turns o after a delay when
welding stops.
Cable Length
10…100 m Step: 5
Factory setting is 10m
Welding cable loop length setting for
optimising arc control.
FineCalib
0V/100A…10V/100A Step: 0.1 V
Factory setting is 1.0V/100A
Fine Tuning Calibration Point. Compensation
for varying cable resistance.
System Clock
System Clock Settings
Device List