MMA PROCESSES
Current
14…350 A Welding current
CurrentMax
14…350 A Set the limit for maximum current value
CurrentMin
14…350 A Set the limit for minimum current value
ArcForce
-9…+9 Factory setting is 0 Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
StartPower
-9…+9 Factory setting is 0 Adjusts arc ignition
CC PROCESS
Current
10…350 A Welding current
CurrentMax
10…350 A Set the limit for maximum current value
CurrentMin
10…350 A Set the limit for minimum current value
Dynamics
-9…+9 Factory setting is 0 Controls the short circuit behaviour of the arc. The
lower the value the softer the arc is. The higher the
value the rougher the arc is.
StartPower
-9…+9 Factory setting is 0 Adjusts arc ignition
CV PROCESS
Voltage
10…50 V Welding voltage
VoltageMax
10…50 V Set the limit for maximum voltage value
VoltageMin
10…50 V Set the limit for minimum voltage value
Dynamics
-9…+9 Factory setting is 0 Controls the short circuit behaviour of the arc. The
lower the value the softer the arc is. The higher the
value the rougher the arc is.
StartPower
-9…+9 Factory setting is 0 Adjusts arc ignition
4.4 Welding functions
WISEROOT+ AND OTHER PROCESSES
2T/4T
2T, 4T, MATCHLOG,
USER
Factory setting is USER (user
chooses the switching logic)
Sets switching logic
HotStart
ON, OFF, USER Factory setting is USER (user
chooses ON or OFF)
HotStartLevel
-50…+100 % Step: 1
Factory setting 40%
Hot 2T Time
0…9.9 s Step: 0.1
Factory setting is 1.2 s
CraterFill
ON, OFF, USER Factory setting is USER (user
chooses ON or OFF)
CraterStart
10…250 % Factory setting is 100% Sets the level of the curve where the crater
lling will start
CraterFillEnd
10…250 %, not
higher than start
Step: 1
Factory setting is 30%
Sets the level of the curve where the crater
lling will end.
CraterTime
0.0…10.0 s Step: 0.1.
Factory setting is 1.0 s
Sets slope time for crate lling