Operation Manual
FastMig X 350, X 450
18
EN
ADVANCED FUNCTIONS
WisePenet
ON, OFF Penetration control selection
Penet%(123A)
-30…+30 % Factory setting: 0 % WisePenetration percent setting. Set
penetration current.
WiseFusion
ON, OFF WiseFusion selection
WiseFusion%
10…60 % or
CURVE
Factory setting is CURVE When WiseFusion is ON, it controls the
amount of short circuits in the arc. The
lower the value, the less short circuits in
the arc, and the higher the value, the more
short circuits in the arc.
MatchFunc *
Minilog, MatchCh
OFF
Default is OFF Selects the type of function for toggling
between two sets of welding parameters
during welding:
Minilog=percentage of base current
MatchCh=alternative memory channel
MinilogLevel
-99…+125 % Factory setting is 20 Sets the alternative current level to a
percentage of the base current
MatchMemChannel
0…9 Factory setting is 0 Sets the pre-dened memory channel,
where the alternative set of parameters is
stored
* MatchFunc is a function that allows you to use two pre-dened sets of welding parameters
during welding. You can toggle between these parameter sets by pressing the welding gun
trigger briey without having to stop welding.